TRANSESOPHAGEAL ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND DYSFUNCTIONING BIOPROSTHETIC VALVES

被引:23
作者
ALAM, M
SERWIN, JB
ROSMAN, HS
POLANCO, GA
SUN, I
SILVERMAN, NA
机构
[1] Henry Ford Heart and Vascular Institute, Department of Anaesthesia, Henry Ford Hospital Detroit, Mich
关键词
D O I
10.1016/0002-8703(91)90676-9
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Transesophageal and transthoracic echocardiography and color flow Doppler were performed in patients with 42 normal and 20 dysfunctioning bioprosthetic mitral and aortic valves. Transesophageal echocardiography was superior to the transthoracic approach in delineating bioprosthetic valve cusps and the presence of valve thickening due to valve degeneration. In 27 clinically normal bioprosthetic mitral valves, regurgitation was demonstrated in three patients by the transthoracic approach and in seven by transesophageal study. Both transesophageal and transthoracic color flow Doppler demonstrated mitral regurgitation in 17 clinically regurgitant valves. The severity of mitral regurgitation was accurately assessed by the transesophageal study in all 13 patients who underwent angiography, whereas the transthoracic imaging underestimated valvular regurgitation in 7 of the 13 cases (54%). Bioprosthetic aortic valves were normal on clinical examination in 15 patients and were regurgitant in three others. Both transthoracic and transesophageal color flow Doppler were of equal value in observing and quantifying aortic regurgitation. In five clinically normal and regurgitant mitral and aortic valves, transesophageal color flow Doppler revealed eccentric regurgitant jets suggestive of paravalvular leak. This feature was not evident by the transthoracic approach. In conclusion, transesophageal echocardiography and color flow Doppler are superior to transthoracic imaging in estimating bioprosthetic mitral, but not aortic regurgitation, in differentiating valvular from paravalvular regurgitation, and in demonstrating thickened valves due to cusp degeneration.
引用
收藏
页码:1149 / 1155
页数:7
相关论文
共 9 条
[1]
COLOR FLOW DOPPLER EVALUATION OF CARDIAC BIOPROSTHETIC VALVES [J].
ALAM, M ;
ROSMAN, HS ;
HAUTAMAKI, K ;
GRAHAM, L ;
MAGILLIGAN, DJ ;
KHAJA, F ;
STEIN, PD .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (19) :1389-1392
[2]
DOPPLER AND ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND DYSFUNCTIONING BIOPROSTHETIC VALVES [J].
ALAM, M ;
ROSMAN, HS ;
LAKIER, JB ;
KEMP, S ;
KHAJA, F ;
HAUTAMAKI, K ;
MAGILLIGAN, DJ ;
STEIN, PD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :851-858
[3]
ECHOCARDIOGRAPHIC CHANGES IN THE THICKNESS OF PORCINE VALVES WITH TIME [J].
ALAM, M ;
GOLDSTEIN, S ;
LAKIER, JB .
CHEST, 1981, 79 (06) :663-668
[4]
COLOR DOPPLER ASSESSMENT OF MITRAL REGURGITATION WITH ORTHOGONAL PLANES [J].
HELMCKE, F ;
NANDA, NC ;
HSIUNG, MC ;
SOTO, B ;
ADEY, CK ;
GOYAL, RG ;
GATEWOOD, RP .
CIRCULATION, 1987, 75 (01) :175-183
[5]
THE PORCINE BIOPROSTHETIC HEART-VALVE - EXPERIENCE AT 15 YEARS [J].
MAGILLIGAN, DJ ;
LEWIS, JW ;
STEIN, P ;
ALAM, M .
ANNALS OF THORACIC SURGERY, 1989, 48 (03) :324-330
[6]
TRANS-ESOPHAGEAL TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND COLOR DOPPLER FLOW VELOCITY MAPPING IN THE EVALUATION OF CARDIAC-VALVE PROSTHESES [J].
NELLESSEN, U ;
SCHNITTGER, I ;
APPLETON, CP ;
MASUYAMA, T ;
BOLGER, A ;
FISCHELL, TA ;
TYE, T ;
POPP, RL .
CIRCULATION, 1988, 78 (04) :848-855
[7]
EVALUATION OF AORTIC-INSUFFICIENCY BY DOPPLER COLOR FLOW MAPPING [J].
PERRY, GJ ;
HELMCKE, F ;
NANDA, NC ;
BYARD, C ;
SOTO, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (04) :952-959
[8]
INVITRO COLOR FLOW, PULSED AND CONTINUOUS WAVE DOPPLER ULTRASOUND MASKING OF FLOW BY PROSTHETIC VALVES [J].
SPRECHER, DL ;
ADAMICK, R ;
ADAMS, D ;
KISSLO, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (06) :1306-1310
[9]
STEWARD JB, 1988, MAYO CLIN P, V63, P649