THE EFFECT OF A THIN COATING OF POLYMETHYLMETHACRYLATE ON THE TORSIONAL FATIGUE-STRENGTH OF THE CEMENT METAL INTERFACE

被引:32
作者
DAVIES, JP
SINGER, G
HARRIS, WH
机构
[1] MASSACHUSETTS GEN HOSP,ORTHOPAED BIOMECH LAB,BOSTON,MA 02114
[2] MASSACHUSETTS GEN HOSP,HIP & IMPLANT UNIT,BOSTON,MA 02114
关键词
D O I
10.1002/jab.770030108
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent studies have established that a mechanism of initiation of failure of fixation of cemented femoral components is debonding of the cement-metal interface. Other studies have shown that the torsional forces induced by stair climbing and rising from a chair are very high. Thus, the interface between the femoral prosthesis and the bone cement in total hip arthroplasty (THA) is required to transmit high torsional loads from the metal to the cement in a cyclic shear mode many times per year. These torsional loads likely contribute to the debonding. This study evaluated the efficacy of a thin layer of polymethylmethacrylate (PMMA) precoating in increasing the torsional fatigue strength of the cement-metal interface. Fatigue studies were performed on 15 specimens. Each specimen was tested with and without PMMA precoating. The PMMA precoat significantly and substantially increased the torsional fatigue strength of the cement-metal interface. Thus, PMMA precoating is likely to be a clinical advantage in maintaining the long-term integrity of the cement-prosthesis interface.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 11 条
[1]  
AHMED A M, 1984, Journal of Orthopaedic Research, V2, P105, DOI 10.1002/jor.1100020201
[2]   THE EFFECT OF SURFACE PREPARATION ON METAL BONE-CEMENT INTERFACIAL STRENGTH [J].
BUNDY, KJ ;
PENN, RW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (06) :773-805
[3]   CEMENT STRAIN-MEASUREMENT SURROUNDING LOOSE AND WELL-FIXED FEMORAL COMPONENT STEMS [J].
CROWNINSHIELD, RD ;
TOLBERT, JR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (05) :819-828
[4]   TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[5]   THE INFLUENCE OF SUPPORT CONDITIONS IN THE LOADING FIXTURE ON FAILURE MECHANISMS IN THE PUSH-OUT TEST - A FINITE-ELEMENT STUDY [J].
HARRIGAN, TP ;
KAREH, J ;
HARRIS, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (05) :678-684
[6]  
HARRIGAN TP, IN PRESS J BIOMECHAN
[7]  
HUISKES R, 1979, ACTA ORTHOP SCAND S, V185
[8]  
MALONEY WJ, 1989, CLIN ORTHOP RELAT R, V249, P129
[9]   THIN-FILM PMMA PRECOATING FOR IMPROVED IMPLANT BONE-CEMENT FIXATION [J].
RAAB, S ;
AHMED, AM ;
PROVAN, JW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (05) :679-704