INTERPRETATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - CONVENTIONAL VERSUS STORAGE PHOSPHOR RADIOGRAPHY

被引:27
作者
KIDO, S
IKEZOE, J
TAKEUCHI, N
KONDOH, H
TOMIYAMA, N
JOKOH, T
KOHNO, N
TAKASHIMA, S
YAMAGAMI, H
NAITO, H
ARISAWA, J
MORIMOTO, S
KOZUKA, T
机构
[1] Department of Radiology, Osaka University Medical School, Fukushima-Ku, Osaka
关键词
DIAGNOSTIC RADIOLOGY; OBSERVER PERFORMANCE; LUNG; INTERSTITIAL DISEASE; RADIOGRAPHY; COMPARATIVE STUDIES; DIGITAL; STORAGE PHOSPHOR; RECEIVER OPERATING CHARACTERISTIC CURVE (ROC);
D O I
10.1148/radiology.187.2.8475302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the reliability of storage phosphor radiography (SR) in diagnosis of subtle interstitial lung abnormalities, the differences among radiologists in interpreting conventional screen-film radiographs and full-size and minified SR images obtained in 80 patients were studied. Forty patients had subtle interstitial lung abnormalities and 40 had no lung abnormalities. Seven chest radiologists and seven residents evaluated the images by using a five-point presence of abnormality scale. Results were evaluated with receiver operating characteristic technique. For all observers, no significant differences were observed among the three image types. For the chest radiologists, significant differences were observed between conventional radiographs and the two SR formats (P < .01). Furthermore, perceptual accuracy was best with conventional radiographs evaluated by chest radiologists. Overall performance with SR and conventional radiography was identical for diagnosis of abnormalities, but detection performance was significantly dependent on observer experience (P < .01 for chest radiologists and P > .01 for residents). For chest radiologists, critically important information may be lost with commercially available SR.
引用
收藏
页码:527 / 533
页数:7
相关论文
共 22 条
[1]   DETECTION OF BULLOUS LUNG-DISEASE - CONVENTIONAL RADIOGRAPHY VS DIGITAL STORAGE PHOSPHOR RADIOGRAPHY [J].
BUCKLEY, KM ;
SCHAEFER, CM ;
GREENE, R ;
AGATSTON, S ;
FAY, J ;
LLEWELLYN, HJ ;
MROSE, HE ;
RUBENS, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (03) :467-470
[2]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[3]   THE COST OF MANAGING DIGITAL DIAGNOSTIC IMAGES [J].
DWYER, SJ ;
TEMPLETON, AW ;
MARTIN, NL ;
LEE, KR ;
LEVINE, E ;
BATNITZKY, S ;
ROSENTHAL, SJ ;
PRESTON, DF ;
PRICE, HI ;
FASZOLD, S ;
ANDERSON, WH ;
COOK, LT .
RADIOLOGY, 1982, 144 (02) :313-318
[4]   EFFICACY OF DIGITAL RADIOGRAPHY FOR THE DETECTION OF PNEUMOTHORAX - COMPARISON WITH CONVENTIONAL CHEST RADIOGRAPHY [J].
ELAM, EA ;
REHM, K ;
HILLMAN, BJ ;
MALONEY, K ;
FAJARDO, LL ;
MCNEILL, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (03) :509-514
[5]   DETECTION OF PNEUMOTHORAX - COMPARISON OF DIGITAL AND CONVENTIONAL CHEST IMAGING [J].
FAJARDO, LL ;
HILLMAN, BJ ;
POND, GD ;
CARMODY, RF ;
JOHNSON, JE ;
FERRELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :475-480
[6]   THE EFFECT OF VARYING SPATIAL-RESOLUTION ON THE DETECTABILITY OF DIFFUSE PULMONARY NODULES - ASSESSMENT WITH DIGITIZED CONVENTIONAL RADIOGRAPHS [J].
FOLEY, WD ;
WILSON, CR ;
KEYES, GS ;
DIBIANCA, FA ;
SCANLON, GT ;
SCHLEUTER, D ;
LAWSON, TL .
RADIOLOGY, 1981, 141 (01) :25-31
[7]  
FRASER RG, 1983, RADIOLOGY, V148, P1
[8]   STORAGE PHOSPHOR RADIOGRAPHS VS CONVENTIONAL FILMS - INTERPRETERS PERCEPTIONS OF DIAGNOSTIC QUALITY [J].
FUHRMAN, CR ;
GUR, D ;
GOOD, B ;
ROCKETTE, H ;
COOPERSTEIN, LA ;
FEIST, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) :1011-1014
[9]   DIGITAL AND CONVENTIONAL CHEST IMAGES - OBSERVER PERFORMANCE WITH FILM DIGITAL RADIOGRAPHY SYSTEM [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
RIMM, AA ;
LAWSON, TL .
RADIOLOGY, 1986, 158 (01) :27-33
[10]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36