DUAL-ENERGY X-RAY ABSORPTIOMETRY AND FORCE-PLATE ANALYSIS OF GAIT IN DOGS WITH HEALED FEMORA AFTER LEG-LENGTHENING PLATE FIXATION

被引:16
作者
MUIR, P [1 ]
MARKEL, MD [1 ]
BOGDANSKE, JJ [1 ]
JOHNSON, KA [1 ]
机构
[1] UNIV WISCONSIN, SCH VET MED, DEPT SURG SCI, COMPARAT ORTHOPAED RES LAB, MADISON, WI 53706 USA
关键词
D O I
10.1111/j.1532-950X.1995.tb01288.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 [兽医学];
摘要
Dual-energy x-ray absorptiometry was used to measure bone mineral density of four regions in healed femora of nine dogs after fracture fixation with a leg-lengthening plate. Six to 85 months (mean, 46 months) after surgery, the bone mineral density of healed femora was not significantly different from the contralateral uninjured femora (P > .05; power = 0.8 at Delta = 15%). Radiolucencies around the proximal screws, apparently associated with screw loosening, were seen on radiographic views of the healed femora of three dogs. In one of these dogs, one screw in the proximal metaphysis had broken. Force-plate analysis of gait was also performed on dogs at the time of bone mineral density measurement. Peak vertical force was decreased in the pelvic limb with the healed fracture compared with the contralateral unoperated limb (P < 0.05). Clinically apparent lameness in three dogs did not appear to be associated with altered bone mineral density and may have been caused by hip osteoarthritis, a nondisplaced hairline diaphyseal fracture, and screw loosening in conjunction with extensive post-traumatic soft tissue injury. (C) Copyright 1995 by The American College of Veterinary Surgeons
引用
收藏
页码:15 / 24
页数:10
相关论文
共 35 条
[1]
EFFECTS OF RIGIDITY OF INTERNAL-FIXATION PLATES ON LONG BONE REMODELING - BIOMECHANICAL AND QUANTITATIVE HISTOLOGICAL STUDY [J].
AKESON, WH ;
WOO, SLY ;
RUTHERFORD, L ;
COUTTS, RD ;
GONSALVES, M ;
AMIEL, D .
ACTA ORTHOPAEDICA SCANDINAVICA, 1976, 47 (03) :241-249
[2]
BEDNAR DA, 1992, CAN J SURG, V35, P428
[3]
Brinker WO, 1984, MANUAL INTERNAL FIXA, P104
[4]
A CUMULATIVE DAMAGE MODEL FOR BONE-FRACTURE [J].
CARTER, DR ;
CALER, WE .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (01) :84-90
[5]
STRESS-ANALYSIS OF A SIMPLIFIED COMPRESSION PLATE FIXATION SYSTEM FOR FRACTURED BONES [J].
CHEAL, EJ ;
HAYES, WC ;
WHITE, AA ;
PERREN, SM .
COMPUTERS & STRUCTURES, 1983, 17 (5-6) :845-855
[7]
COOK SD, 1985, CLIN ORTHOP RELAT R, P236
[8]
X-RAY DUAL-PHOTON ABSORPTIOMETRY - A NEW METHOD FOR THE MEASUREMENT OF BONE-DENSITY [J].
CULLUM, ID ;
ELL, PJ ;
RYDER, JP .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (739) :587-592
[9]
NEW BONE-FORMATION DURING LEG LENGTHENING - EVALUATED BY DUAL ENERGY X-RAY ABSORPTIOMETRY [J].
EYRES, KS ;
BELL, MJ ;
KANIS, JA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (01) :96-106
[10]
A NEW TECHNIQUE FOR REPAIR OF COMMINUTED DIAPHYSEAL FRACTURES [J].
FREY, AJ ;
OLDS, R .
VETERINARY SURGERY, 1981, 10 (01) :51-57