ESTIMATED FETAL RADIATION-DOSE FROM MULTISLICE CT STUDIES

被引:58
作者
FELMLEE, JP [1 ]
GRAY, JE [1 ]
LEETZOW, ML [1 ]
PRICE, JC [1 ]
机构
[1] MAYO CLIN & MAYO FDN,DEPT DIAGNOST RADIOL,ROCHESTER,MN 55905
关键词
D O I
10.2214/ajr.154.1.2104708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360° and 398°) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered. The data presented here can be used to estimate fetal dose to within ±15% of the measured value for scans up to 40 cm from the fetus.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 10 条
[1]  
DREXLER G, 1985, GSF S1026 GES STRAHL
[2]   NORMALIZED PEDIATRIC ORGAN-ABSORBED DOSES FROM CT EXAMINATIONS [J].
FEARON, T ;
VUCICH, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :171-174
[3]   NORMALIZED ORGAN DOSES FOR VARIOUS DIAGNOSTIC RADIOLOGIC PROCEDURES [J].
GRAY, JE ;
RAGOZZINO, MW ;
VANLYSEL, MS ;
BURKE, TM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (03) :463-470
[4]  
KEREIAKES JG, 1980, HDB RAD DOSES NUCLEA
[5]  
MCCULLOUGH EC, 1978, MED PHYS, V4, P85
[6]   ESTIMATION AND MINIMIZATION OF FETAL ABSORBED DOSE - DATA FROM COMMON RADIOGRAPHIC EXAMINATIONS [J].
RAGOZZINO, MW ;
GRAY, JE ;
BURKE, TM ;
VANLYSEL, MS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (04) :667-671
[7]  
ROSENSTEIN MD, 1988, DHEW FDA898031 PUBL
[8]   A METHOD FOR DESCRIBING THE DOSES DELIVERED BY TRANSMISSION-X-RAY COMPUTED-TOMOGRAPHY [J].
SHOPE, TB ;
GAGNE, RM ;
JOHNSON, GC .
MEDICAL PHYSICS, 1981, 8 (04) :488-495
[9]  
Wagner L.K., 1985, EXPOSURE PREGNANT PA, Vxiii
[10]   CONCEPTUS DOSE FROM 2 STATE-OF-THE-ART CT SCANNERS [J].
WAGNER, LK ;
ARCHER, BR ;
ZECK, OF .
RADIOLOGY, 1986, 159 (03) :787-792