VASCULAR EROSION CAUSED BY A DOUBLE-LUMEN CENTRAL VENOUS CATHETER DURING THERAPEUTIC PLASMA-EXCHANGE

被引:3
作者
QUILLEN, K [1 ]
MAGARACE, L [1 ]
FLANAGAN, J [1 ]
BERKMAN, EM [1 ]
机构
[1] BLOOD BANK,BOSTON,MA
关键词
D O I
10.1046/j.1537-2995.1995.35695288772.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The use of large-bore double-lumen dialysis catheters has simplified the procedure of therapeutic plasma exchange, but these catheters are associated with unusual and possibly life-threatening complications. Case Report: A 46-year-old black man was admitted to the hospital with acute onset of paresthesia and weakness. A diagnosis of Guillain-Barre syndrome was made. Plasma exchange therapy was instituted by peripheral venous access. After three such exchanges, a double-lumen central venous catheter was placed via the left subclavian vein on hospital Day 7. The patient experienced a sudden onset of severe chest pain and dyspnea during the fourth plasma exchange. He became diaphoretic and hypotensive and experienced tachycardia. The apheresis procedure was stopped. Because of worsening respiratory distress, endotracheal intubation was performed. A chest x-ray revealed a large right pleural effusion. The central venous catheter was removed. A chest tube was placed, and a large amount of bloody fluid was drained. Several days later, the endotracheal and chest tubes were removed. Conclusion: An unusual complication of the use of a central venous catheter, erosion of the superior vena cava, occurred during therapeutic plasma exchange. Prompt recognition of this complication and appropriate therapy can be life-saving.
引用
收藏
页码:510 / 512
页数:3
相关论文
共 10 条
[1]   HEMOTHORAX DUE TO VENA-CAVAL EROSION BY A SUBCLAVIAN DUAL-LUMEN DIALYSIS CATHETER [J].
CARBONE, K ;
GIMENEZ, LF ;
ROGERS, WH ;
WATSON, AJ .
SOUTHERN MEDICAL JOURNAL, 1987, 80 (06) :795-796
[2]   CONTRALATERAL EFFUSIONS SECONDARY TO SUBCLAVIAN VENOUS CATHETERS REPORT OF 2 CASES [J].
CIMENT, LM ;
ROTBART, A ;
GALBUT, RN .
CHEST, 1983, 83 (06) :926-928
[3]   COMPLICATIONS OF THERAPEUTIC PLASMA-EXCHANGE - A RECENT ASSESSMENT [J].
COURIEL, D ;
WEINSTEIN, R .
JOURNAL OF CLINICAL APHERESIS, 1994, 9 (01) :1-5
[4]   VASCULAR EROSION BY CENTRAL VENOUS CATHETERS - CLINICAL-FEATURES AND OUTCOME [J].
DUNTLEY, P ;
SIEVER, J ;
KORWES, ML ;
HARPEL, K ;
HEFFNER, JE .
CHEST, 1992, 101 (06) :1633-1638
[5]   CENTRAL VENOUS CATHETER VASCULAR EROSIONS - DIAGNOSIS AND CLINICAL COURSE [J].
ELLIS, LM ;
VOGEL, SB ;
COPELAND, EM .
ANNALS OF SURGERY, 1989, 209 (04) :475-478
[6]  
Huestis D W, 1984, J Clin Apher, V2, P81, DOI 10.1002/jca.2920020113
[7]  
HUESTIS DW, 1983, LANCET, V1, P1043
[8]  
IBERTI TJ, 1983, SURGERY, V94, P842
[9]  
RUSSELL SJ, 1987, LANCET, V1, P568
[10]   COMPLICATIONS OF PLASMA-EXCHANGE [J].
SUTTON, DMC ;
NAIR, RC ;
ROCK, G .
TRANSFUSION, 1989, 29 (02) :124-127