ANALYSIS OF POLYCHLORODIBENZO-PARA-DIOXINS IN RAW AND TREATED WATERS .2. OPTIMIZATION OF AN XAD-2 RESIN COLUMN METHODOLOGY

被引:9
作者
LEBEL, G
WILLIAMS, DT
HOLLEBONE, BR
SHEWCHUK, C
BROWNLEE, LJ
TOSINE, H
CLEMENT, R
SUTER, S
机构
[1] CARLETON UNIV,DEPT CHEM,OTTAWA K1S 5B6,ONTARIO,CANADA
[2] MINIST ENVIRONM,LAB SERV BRANCH,REXDALE,ONTARIO,CANADA
关键词
dioxin; PCDD; water analysis; XAD-2; resin;
D O I
10.1080/03067319008026910
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several operating parameters were evaluated to assess the efficiency of an XAD-2 resin column for use in an automated sampling unit to be developed for the analysis of polychlorodibenzo-p-dioxins (PCDDs) in water. Direct standard addition of mass labelled congeners onto the column were used to evaluate the capacity of the resin for PCDDs. Ratios of resin volume and bed volume flow rates were systematically varied. Flow rates of 3 to 24 bed volumes per minute were used without observable breakthrough. Column behaviour was evaluated using the continuous standard addition technique to determine the optimum flow rate for minimal breakthrough, which was found to be 3 bed volume/min. PCDD recoveries were quantitative (>75%) except for octachlorodibenzodioxin where lower recoveries (approximately 40%) were due to losses in the cleanup procedure and not to the sampling. Recoveries of the five congeners used in this study confirm that XAD-2 resin exhibits an extracting capability of organic contaminants from water equal to that of liquid-liquid extraction and allows both a much larger sample size and easier sampling. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 13 条
[1]   EVALUATION OF A TEFLON HELIX LIQUID LIQUID EXTRACTOR FOR CONCENTRATIN OF TRACE ORGANICS FROM WATER INTO METHYLENE-CHLORIDE [J].
BAKER, RJ ;
GIBS, J ;
MENG, AK ;
SUFFET, IH .
WATER RESEARCH, 1987, 21 (02) :179-190
[2]   Screening methodology for coal-derived organic contaminants in water [J].
McElmurry, SP ;
Voice, TC .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2004, 84 (04) :277-287
[3]   ANALYSIS OF POLYCHLORODIBENZO-PARA-DIOXINS IN RAW AND TREATED WATERS .1. EVALUATION OF GRAB SAMPLE METHODOLOGY FOR PART-PER-QUADRILLION ANALYSIS [J].
HOLLEBONE, BR ;
SHEWCHUK, C ;
BROWNLEE, LJ ;
TOSINE, H ;
CLEMENT, R ;
SUTER, S ;
LEBEL, G ;
WILLIAMS, DT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (01) :9-20
[4]   USE OF MACRORETICULAR RESINS IN ANALYSIS OF WATER FOR TRACE ORGANIC CONTAMINANTS [J].
JUNK, GA ;
RICHARD, JJ ;
GRIESER, MD ;
WITIAK, D ;
WITIAK, JL ;
ARGUELLO, MD ;
VICK, R ;
SVEC, HJ ;
FRITZ, JS ;
CALDER, GV .
JOURNAL OF CHROMATOGRAPHY, 1974, 99 (NOV6) :745-762
[6]  
LEBEL GL, 1979, J ASSOC OFF ANA CHEM, V62, P241
[7]  
LEBEL GL, 1981, J ASSOC OFF ANA CHEM, V64, P991
[8]  
LEBEL GL, 1986, CHLORINATED DIOXINS, P329
[9]   REVERSE-PHASE ADSORBENT CARTRIDGE FOR TRAPPING DIOXINS IN DRINKING-WATER [J].
OKEEFE, P ;
MEYER, C ;
SMITH, R ;
HILKER, D ;
ALDOUS, K ;
WILSON, L .
CHEMOSPHERE, 1986, 15 (9-12) :1127-1134
[10]   FIELD TESTING OF A LARGE VOLUME LIQUID-LIQUID-EXTRACTION DEVICE FOR HALOGENATED ORGANICS IN NATURAL-WATERS [J].
OLIVER, BG ;
NICOL, KD .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1986, 25 (04) :275-285