DETERMINATION OF TOTAL AND FREE SULFUR-DIOXIDE IN WINE WITH A CONTINUOUS-FLOW MICRODISTILLATION SYSTEM

被引:29
作者
MAQUIEIRA, A [1 ]
CASAMAYOR, F [1 ]
PUCHADES, R [1 ]
SAGRADO, S [1 ]
机构
[1] UNIV VALENCIA,DEPT QUIM ANALIT,E-46100 BURJASSOT,SPAIN
关键词
FLOW INJECTION; UV VISIBLE SPECTROPHOTOMETRY; DISTILLATION; SULFUR DIOXIDE; WINES;
D O I
10.1016/0003-2670(93)85250-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A continuous-flow microdistillation system for the determination of SO2 (free and total) in wine samples is described. The assembly Permits the successive addition of discrete volumes of sample to the microdistillation module with the aid of a nitrogen carrier stream. The nitrogen carrier also transports the volatillized SO2, after the distillation step, to the absorption module, where the analyte reacts with a solution of 2,2'-dinitro-5,5'-dithiodibenzoic acid in phosphate buffer (pH 6) to give a yellow derivative, which is monitored spectrophotometrically at 410 nm. Free and total SO2 signals are obtained by operating the microdistillation module at room temperature (ca. 20-degrees-C) and 100-degrees-C, respectively. Total SO2 requires a previous hydrolysis step, which is carried out on-line with the aid of 4 M NaOH. Chemical and physical parameters were optimized. The influence of some common compounds usually present in wine samples on the analytical signal was also studied. The proposed procedure was compared with two recommended methods: the EEC reference distillation method and the EEC iodimetric method. The proposed method was found to be equally suitable to the reference distillation method, for the rapid and accurate control of wine samples, and additionally competes advantageously with the iodimetric method.
引用
收藏
页码:401 / 407
页数:7
相关论文
共 13 条
[1]  
BARTROLI J, 1991, ANAL CHEM, V63, P2535
[2]  
BROWN DS, 1987, ANALYST, V112, P889
[3]   DETERMINATION OF SULFUR-DIOXIDE IN WHITE WINES BY FLOW-INJECTION WITH ELECTROCHEMICAL DETECTION [J].
CARDWELL, TJ ;
CATTRALL, RW ;
NAN, CG ;
ILES, PJ ;
HAMILTON, IC ;
SCOLLARY, GR .
ELECTROANALYSIS, 1991, 3 (08) :859-863
[4]  
GARZAULLOA H, 1980, BREWERS DIG, V55, P20
[5]  
JUAN EE, 1991, Patent No. 9102435
[6]   DOUBLY STOPPED FLOW - A NEW ALTERNATIVE TO SIMULTANEOUS KINETIC MULTIDETERMINATIONS IN UNSEGMENTED FLOW SYSTEMS [J].
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1987, 59 (07) :950-954
[7]  
Monier-Williams G., 1927, REP PUBL HLTH MED SU, V43, P1
[8]  
SULLIVAN JJ, 1990, J ASSOC OFF ANA CHEM, V73, P35
[9]  
SULLIVAN JJ, 1990, J ASSOC OFF ANA CHEM, V73, P223
[10]  
VAHL JM, 1980, J ASSOC OFF ANA CHEM, V63, P194