QUANTITATIVE COMPUTER IMAGE-ANALYSIS OF A HUMAN CHORIONIC-GONADOTROPIN COLLOIDAL CARBON DIPSTICK ASSAY

被引:23
作者
VANAMERONGEN, A [1 ]
VANLOON, D [1 ]
BERENDSEN, LBJM [1 ]
WICHERS, JH [1 ]
机构
[1] ST ANTONIUS HOSP,DEPT CLIN CHEM,3430 EM NIEUWEGEIN,NETHERLANDS
关键词
COLLOIDAL CARBON; HUMAN CHORIONIC GONADOTROPIN; SOL PARTICLE IMMUNOASSAY; DIPSTICK; QUANTIFICATION; COMPUTER IMAGE ANALYSIS;
D O I
10.1016/0009-8981(94)90229-1
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Colloidal particles are widely used in qualitative dipstick assays for the determination of various proteins and haptens. Recently, a new colloidal label has been introduced based on elemental carbon. With this carbon label we have prepared a human chorionic gonadotropin-specific dipstick assay with a sensitivity of 10 mIU/ml, In addition, an image- and dataprocessing procedure for the quantification of the dipstick assay has been developed. The sum of the pixel grey levels of a carbon line was taken as a measure for this quantitative purpose. The measurement range of the assay is almost three orders of magnitude, i.e. 10 mIU/ml to 500 mIU/ml. The deviation from the mean of two dipstick determinations was 1.22% on average. The within-run and between-run precision, expressed as coefficients of variation at 50 mIU/ml were 1.03% and 1.84%, at 150 mIU/ml 2.14% and 3.77% and at 450 mIU/ml 2.55% and 5.28%, respectively. We have correlated this quantitative sol particle immunoassay with a commercial human chorionic gonadotropin specific radioimmunoassay. In an experiment with 25 human urine samples containing the hormone in amounts from 5 to 300 mIU/ml the correlation coefficient was 0.999. The sol particle immunoassay quantified by computer image analysis has been termed Sol particle Image Processed Immuno Assay (SIPIA).
引用
收藏
页码:67 / 75
页数:9
相关论文
共 29 条
[1]   SPECIFICITY AND DETECTION LIMIT OF 10 PREGNANCY TESTS [J].
ALFTHAN, H ;
BJORSES, UM ;
TIITINEN, A ;
STENMAN, UH .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1993, 53 :105-113
[2]   NEW SEMIQUANTITATIVE DIPSTICK TEST FOR MICROALBUMINURIA [J].
BANGSTAD, HJ ;
TRY, K ;
DAHLJORGENSEN, K ;
HANSSEN, KF .
DIABETES CARE, 1991, 14 (11) :1094-1097
[3]  
Barbara D. J., 1986, IMMUNOLOGY PLANT SCI, P197
[4]   LATEX IMMUNOASSAY OF TRANSFERRIN IN URINE [J].
BERNARD, A ;
CHIA, KS ;
LAUWERYS, R .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 144 (01) :49-55
[5]   LATEX-BASED THIN-LAYER IMMUNOAFFINITY CHROMATOGRAPHY FOR QUANTITATION OF PROTEIN ANALYTES [J].
BIRNBAUM, S ;
UDEN, C ;
MAGNUSSON, CGM ;
NILSSON, S .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) :168-171
[6]  
CONE R, 1985, J MED TECHNOL, V2, P279
[7]  
CORNBLEET PJ, 1979, CLIN CHEM, V25, P432
[8]  
Davidson Ian W., 1992, Analytical Proceedings, V29, P459, DOI 10.1039/ap9922900459
[9]  
DEJONGE H, 1963, INLEIDING TOT MED ST
[10]  
GOSLING JP, 1990, CLIN CHEM, V36, P1408