LENS REFILLING AND ENDOCAPSULAR POLYMERIZATION OF AN INJECTABLE INTRAOCULAR-LENS - IN-VITRO AND IN-VIVO STUDY OF POTENTIAL RISKS AND BENEFITS

被引:48
作者
HETTLICH, HJ
LUCKE, K
ASIYOVOGEL, MN
SCHULTE, M
VOGEL, A
机构
[1] Clinic for Ophthalmology, Medical University of Lubeck
[2] Medical Laser Center, Medical University of Lubeck
关键词
BIOCOMPATIBILITY; ENDOCAPSULAR POLYMERIZATION; LENS REFILLING; SECONDARY OPACIFICATION;
D O I
10.1016/S0886-3350(13)80149-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Endocapsular cataract removal and injection of a liquid artificial lens has several advantages, including restitution of accommodation, small corneoscleral incision, a more physiological position of the intraocular lens, and a reduced rate of secondary opacification. Our technique consists of bimanual phacofragmentation followed by injection of a fluid monomeric material that can be polymerized inside the capsular bag by short light exposure. Our study assessed the potential risks of the technique (e.g., heat damage to ocular tissue, light damage to the retina) and investigated the technique in vivo. We performed in vitro experiments on porcine cadaver eyes and an in vivo study on 1 5 rabbits. After a clinical follow-up of at least 12 weeks, the eyes were investigated histopathologically. During the polymerization process, the highest temperature measured at the posterior lens capsule was 45.1 degrees Celsius for a few seconds. The measured irradiance (0.065 watts per cm2) and the risk of photochemical damage to the retina during 20 seconds of polymerization were comparable to that caused by 1.5 minutes of standard coaxial illumination with the operating microscope. In vivo there were no serious inflammatory reactions except in four Gases in which there had been intraoperative problems. The rate of secondary opacification appeared less than in conventional intraocular lens implantation in rabbits, especially when the capsule refilled completely. Retinal damage could not be detected histopathologically. In conclusion, refilling techniques may be successful once appropriate refilling materials become available.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 20 条
[1]  
Kessler J, Experiments in refilling the lens, Arch Ophthalmol, 71, pp. 412-417, (1964)
[2]  
Kessler J, Refilling the rabbit lens: further experiments, Arch Ophthalmol, 76, pp. 596-598, (1966)
[3]  
Agarwal LP, Narsimhan EC, Mohan M, Experimental lens refilling, Orient Arch Ophthalmol, 5, pp. 205-212, (1967)
[4]  
Parel J-M, Gelender H, Trefers WF, Norton EWD, PhacoErsatz: cataract surgery designed to preserve accommodation, Graefes Arch Clin Exp Ophthalmol, 224, pp. 165-173, (1986)
[5]  
Gindi JJ, Wan WL, Kash R, Schanzlin DJ, Endocapsular cataract surgery: effects on the corneal endothelium. ARVO Abstracts, Invest Ophthalmol Vis Sci, 25, (1984)
[6]  
Gindi JJ, Lee Wan W, Schanzlin DJ, Endocapsular cataract surgery-I. Surgical technique, Cataract, 2, 5, pp. 6-10, (1985)
[7]  
Wan WL, Gindi JJ, Schanzlin DJ, Endocapsular cataract surgery-II. Effects on the corneal endothelium, Cataract, 2, 5, pp. 11-14, (1985)
[8]  
Hara T, Hara T, Endocapsular phacoemulsification and aspiration (ECPEA)-recent surgical technique and clinical results, Ophthalmic Surg, 20, pp. 469-475, (1989)
[9]  
Nishi O, Hara T, Hara T, Et al., Further development of experimental techniques for refilling the lens of animal eyes with a balloon, J Cataract Refract Surg, 15, pp. 584-588, (1989)
[10]  
Haefliger E, Parel J-M, Fantes F, Et al., Accommodation of an endocapsular silicone lens (phaco-Ersatz) in the nonhuman primate, Ophthalmology, 94, pp. 471-477, (1987)