ABSOLUTE CROSS-SECTIONAL AREA MEASUREMENTS IN QUANTITATIVE CORONARY ARTERIOGRAPHY BY DUAL-ENERGY DSA

被引:19
作者
MOLLOI, SY
ERSAHIN, A
ROECK, WW
NALCIOGLU, O
机构
[1] Department of Radiological Sciences, Division of Physics and Engineering, University of California, Irvine, CA
关键词
QUANTITATIVE ARTERIOGRAPHY; DIGITAL SUBTRACTION ANGIOGRAPHY; ENERGY SUBTRACTION;
D O I
10.1097/00004424-199102000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent studies have emphasized the limitations of conventional coronary angiography. These limitations include the lack of correlation between the severity of coronary stenosis as estimated from coronary angiograms and the actual severity of stenotic lesions measured in postmortem hearts. As a result, attempts have been made to quantitate luminal dimension more precisely. The application of quantitative digital subtraction angiography (DSA) in the assessment of coronary artery lesion dimension has been limited by cardiac and respiratory motion artifacts. We have reported previously on a motion-immune dual-energy (DE) cardiac mode in which kVp and filtration are switched at 30 Hz. To assess the potential advantages of a videodensitometric technique for quantification of absolute vessel cross-sectional area (CSA), three different quantitative coronary arteriography (QCA) algorithms were compared. The three algorithms under comparison were a videodensitometric (V) algorithm, which does not require any geometric assumption for absolute vessel CSA measurement, and videodensitometric (VC) and edge detection (ED) algorithms, which do require the assumption of circular cross-section for CSA measurements. A cylindrical vessel phantom (0.5-4.75 mm in diameter) and a crescentic vessel phantom, producing 25% to 90% area stenosis, were imaged over the chest of a humanoid phantom. The low- and high-energy images were corrected for scatter and veiling glare before energy subtraction. For CSA measurements in crescentic vessel phantoms, the V algorithm produced significantly improved results (slope = 0.87, intercept = 0.51 mm2, r = .95) when compared to the VC (slope = 1.05, intercept = 4.19 mm2, r = .75) and the ED (slope = 1.57, intercept = 5.21 mm2, r = .60) algorithms.
引用
收藏
页码:119 / 127
页数:9
相关论文
共 32 条
[1]   QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION [J].
BROWN, BG ;
BOLSON, E ;
FRIMER, M ;
DODGE, HT .
CIRCULATION, 1977, 55 (02) :329-337
[2]  
BURSCH JH, 1988, PROGR DIGITAL ANGIOC, P201
[3]   OBSERVER AGREEMENT IN EVALUATING CORONARY ANGIOGRAMS [J].
DETRE, KM ;
WRIGHT, E ;
MURPHY, ML ;
TAKARO, T .
CIRCULATION, 1975, 52 (06) :979-986
[4]   DETAILS OF CORONARY STENOSIS MORPHOLOGY INFLUENCE ITS HEMODYNAMIC SEVERITY AND DISTAL FLOW RESERVE [J].
FEDELE, FA ;
SHARAF, B ;
MOST, AS ;
GEWIRTZ, H .
CIRCULATION, 1989, 80 (03) :636-642
[5]   ACCURATE ANALYSIS OF BLOOD-VESSEL SIZES AND STENOTIC LESIONS USING STEREOSCOPIC DSA SYSTEM [J].
FENCIL, LE ;
DOI, K ;
HOFFMAN, KR .
INVESTIGATIVE RADIOLOGY, 1988, 23 (01) :33-41
[6]   REPRODUCIBILITY OF CORONARY ARTERIOGRAPHIC READING IN THE CORONARY-ARTERY SURGERY STUDY (CASS) [J].
FISHER, LD ;
JUDKINS, MP ;
LESPERANCE, J ;
CAMERON, A ;
SWAYE, P ;
RYAN, T ;
MAYNARD, C ;
BOURASSA, M ;
KENNEDY, JW ;
GOSSELIN, A ;
KEMP, H ;
FAXON, D ;
WEXLER, L ;
DAVIS, KB .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (06) :565-575
[7]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .2. COMPUTERIZED DETERMINATION OF VESSEL SIZES IN DIGITAL SUBTRACTION ANGIOGRAPHY [J].
FUJITA, H ;
DOI, K ;
FENCIL, LE ;
CHUA, KG .
MEDICAL PHYSICS, 1987, 14 (04) :549-556
[8]   SELECTIVE CORONARY ANGIOGRAPHY USING A POWER INJECTOR [J].
GARDINER, GA ;
MEYEROVITZ, MF ;
BOXT, LM ;
HARRINGTON, DP ;
TAUS, RH ;
KANDARPA, K ;
GANZ, P ;
SELWYN, AP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (04) :831-833
[9]  
GRONDIN CM, 1974, CIRCULATION, V49, P703
[10]  
HANGIANDREOU NJ, 1990, THESIS U WISCONSIN M, P22