RADIATION EXPOSURE OF RADIOLOGISTS DURING ANGIOGRAPHY - DOSE MEASUREMENTS OUTSIDE THE LEAD APRON

被引:4
作者
FISCHER, H [1 ]
PRZETAK, C [1 ]
TEUBERT, G [1 ]
EWEN, K [1 ]
MODDER, U [1 ]
机构
[1] LANDESANSTALT ARBEITSSCHUTZ,DUSSELDORF,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1995年 / 162卷 / 02期
关键词
ANGIOGRAPHY; RADIOPROTECTION; BODY PARTS DOSES; THERMOLUMINESCENCE DOSIMETER;
D O I
10.1055/s-2007-1015852
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r = 0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 21 条
[1]  
EWEN K, 1973, ROFO FORTSCHR RONTG, V118, P715
[2]   AN ASSESSMENT OF THE RADIATION-DOSE RECEIVED BY STAFF USING FLUOROSCOPIC EQUIPMENT [J].
FAULKNER, K ;
MOORES, BM .
BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (652) :272-276
[3]   PERSONNEL EXPOSURE TO RADIATION AT SOME ANGIOGRAPHIC PROCEDURES [J].
GUSTAFSSON, M ;
LUNDERQUIST, A .
RADIOLOGY, 1981, 140 (03) :807-811
[4]   RADIATION PROTECTION CONSIDERATIONS OF OVERHEAD FLUOROSCOPIC INSTALLATIONS [J].
JACOBSON, A .
HEALTH PHYSICS, 1971, 20 (01) :55-+
[5]   AN INVESTIGATION OF THE RADIATION-DOSE TO STAFF DURING CARDIAC RADIOLOGICAL STUDIES [J].
JEANS, SP ;
FAULKNER, K ;
LOVE, HG ;
BARDSLEY, RA .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (689) :419-428
[6]  
KRAHE T, 1986, ROFO FORTSCHR RONTG, V145, P217
[7]   RADIATION EXPOSURE OF OPERATOR DURING ANGIOGRAPHY [J].
LACKNER, K ;
EWEN, K ;
FELIX, R .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1978, 128 (01) :86-90
[8]   DOSES TO HEAD AND ARMS OF RADIOLOGISTS DURING FLUOROSCOPY [J].
LAW, J .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (686) :187-188
[9]  
MARTIGNONI K, 1991, RADIOLOGE, V31, P235
[10]  
MARX V, 1992, J VASC INTERV RADIOL, V3, P597