COMBINED USE OF OZONE AND GRANULAR ACTIVATED CARBON (GAC) IN POTABLE WATER-TREATMENT - EFFECTS ON GAC QUALITY AFTER REACTIVATION

被引:9
作者
BOERE, JA
机构
[1] NORIT N.V., 3800 AC Amersfoort, Nijverheidsweg-Noord 72
关键词
OZONE; DRINKING WATER TREATMENT; OZONE + GAC TREATMENT; GAC PROPERTIES AFTER REACTIVATION; NATURAL ORGANIC MATTER; ORGANIC MICROPOLLUTANTS; PREOZONATION; CHLORINE DIOXIDE;
D O I
10.1080/01919519208552294
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Common processes in potable water treatment regarding dissolved organics removal (natural organic matter, NOM, and organic micropollutants, OMP) include oxidation techniques - like ozonation -and adsorption onto granular activated carbon (GAC). This paper deals with combined ozonation and GAC filtration. Effects on water quality are discussed: partial oxidation of dissolved organics by ozone, leading to changing adsorption behavior and enhanced biodegradation in GAC columns. Special emphasis is laid on long term effects of ozone on GAC quality after several thermal reactivations. Long term experience indicates that ozonation prior to GAC filtration, leading to moderate ozone concentrations in the GAC influent, does not influence GAC quality negatively, even after more than ten reactivation cycles.
引用
收藏
页码:123 / 137
页数:15
相关论文
共 20 条
[1]  
BRENER L, 1983, EAU, V78, P569
[2]  
BRUCHET A, 1987, ADV CHEM SERIES, V214
[3]  
CAIRO PR, 1982, J AM WATER WORKS ASS, V74, P94
[4]  
HARRINGTON GW, 1989, J AM WATER WORKS ASS, V81, P93
[5]  
HARRINGTON GW, 1989, ADV CHEM SERIES, V219
[6]  
HOERNER G, 1986, VOM WASSER, V66, P177
[7]  
KRUITHOF JC, 1989, ADV CHEM SERIES, V219
[8]  
KUHN W, 1973, VOM WASSER, V40, P116
[9]   OZONATION OF AN EXTRACTED AQUATIC FULVIC-ACID - THEORETICAL AND PRACTICAL ASPECTS [J].
LEGUBE, B ;
CROUE, JP ;
DELAAT, J ;
DORE, M .
OZONE-SCIENCE & ENGINEERING, 1989, 11 (01) :69-91
[10]  
MCGUIRE MJ, 1989, WASSER BERLIN 89