STANDARDIZED PROCEDURE FOR THE ASSAY AND IDENTIFICATION OF HYPOGLYCEMIC SULFONYLUREAS IN HUMAN PLASMA

被引:25
作者
SENER, A [1 ]
AKKAN, AG [1 ]
MALAISSE, WJ [1 ]
机构
[1] FREE UNIV BRUSSELS,ERASMUS SCH MED,EXPTL MED LAB,B-1070 BRUSSELS,BELGIUM
关键词
HYPOGLYCEMIC SULFONYLUREA; GLICLAZIDE; GLIPIZIDE; GLIQUIDONE; GLIBENCLAMIDE;
D O I
10.1007/BF00581049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A standardized procedure for the assay and identification of hypoglycemic sulfonylureas in plasma is presented. External standards and plasma extracts containing glibenclamide, gliquidone, glipizide, or gliclazide were examined by high-performance liquid chromatography. The four sulfonylureas could be identified and measured with a precision of 5%-7% and a limit of detection close to 1-2 ng in injected external standards and 10-40 ng/ml in plasma samples. This method is suitable to study the pharmacokinetics of hypoglycemic sulfonylureas, for blood drug monitoring in diabetic patients, for diagnostic purposes in factitious hypoglycemia, and in cases relevant to forensic medicine.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 6 条
[1]  
DELEERS M, 1984, DIABETOLOGIA, V26, P55
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF GLIPIZIDE IN HUMAN-PLASMA AND URINE [J].
EMILSSON, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 421 (02) :319-326
[3]  
KAPITAR Z, 1975, ARZNEIMITTELF FORSCH, V25, P1469
[4]   SIMULTANEOUS DETERMINATION OF THE SULFONYLUREA GLIMEPIRIDE AND ITS METABOLITES IN HUMAN SERUM AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER PRECOLUMN DERIVATIZATION [J].
LEHR, KH ;
DAMM, P .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 526 (02) :497-505
[5]   DETERMINATION OF GLIBENCLAMIDE AND ITS 2 MAJOR METABOLITES IN HUMAN SERUM AND URINE BY COLUMN LIQUID-CHROMATOGRAPHY [J].
RYDBERG, T ;
WAHLINBOLL, E ;
MELANDER, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (01) :223-233
[6]  
SENER A, 1995, IN PRESS DIAB MED