AN ENHANCED SENSITIVITY K-SHELL X-RAY-FLUORESCENCE TECHNIQUE FOR TIBIAL LEAD DETERMINATION

被引:29
作者
GREEN, S [1 ]
BRADLEY, DA [1 ]
PALETHORPE, JE [1 ]
MEARMAN, D [1 ]
CHETTLE, DR [1 ]
LEWIS, AD [1 ]
MOUNTFORD, PJ [1 ]
MORGAN, WD [1 ]
机构
[1] MCMASTER UNIV,DEPT PHYS,HAMILTON L8S 4M1,ONTARIO,CANADA
关键词
D O I
10.1088/0031-9155/38/3/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel irradiation-detection geometry capable of enhancing sensitivity for the measurement of tibial lead content by K-shell x-ray fluorescence (XRF) is described. The high-count-rate system comprised a small-area high-specific-activity (0.147 GBq mm-2) Cd-109 source and a large-area (nominally 20 cm2) uncollimated detector, forming an axially symmetric back-scattering arrangement. Precisions in the range +/-4.9 to +/-14.2 mug Pb (g bone mineral)-1 have been obtained in a study of a cohort of 63 controls and 73 workers industrially exposed to lead. These precisions are comparable with those obtained in results using earlier systems, but at reduced source activities (less than 50% of the activity of other systems) and with significant reduction in measurement time (some 30% less than the measurement times of other systems). Subsequent investigation of detector collimation resulted in a marginal improvement in energy resolution, but the restriction in detected photon fluence meant that there was an insignificant change in detection sensitivity. For the resistive feedback preamplifier used in this study a maximum energy rate of the order of 7000 MeV s-1 was found to limit measurement precisions significantly. Higher-count-rate detector systems offer a basis for obtaining mean precisions down to +/-3 mug Pb (g bone mineral)-1 at one standard deviation.
引用
收藏
页码:389 / 396
页数:8
相关论文
共 11 条
[1]  
AHLGREN L, 1980, BRIT J IND MED, V37, P109
[2]   X-RAY-FLUORESCENCE TECHNIQUE FOR INVIVO DETERMINATION OF LEAD CONCENTRATION IN A BONE-MATRIX [J].
AHLGREN, L ;
MATTSSON, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (01) :136-145
[3]  
AHLGREN L, 1976, Scandinavian Journal of Work Environment and Health, V2, P82
[4]  
ARMSTRONG R, 1992, BRIT J IND MED, V49, P14
[5]   LEAD IN BONE - SAMPLING AND QUANTITATION USING K X-RAYS EXCITED BY CD-112 [J].
CHETTLE, DR ;
SCOTT, MC ;
SOMERVAILLE, LJ .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1991, 91 :49-55
[6]  
JONES KW, 1987, IN VIVO BODY COMPOSI, P363
[7]   THE COMPTON PROFILE OF BISMUTH EXCITED BELOW THE K-ABSORPTION EDGE [J].
MACKENZIE, IK ;
STONE, RJ .
SOLID STATE COMMUNICATIONS, 1985, 55 (08) :751-754
[8]   AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS [J].
MARQUARDT, DW .
JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02) :431-441
[9]   INVIVO MEASUREMENT OF LEAD IN BONE USING X-RAY-FLUORESCENCE [J].
SOMERVAILLE, LJ ;
CHETTLE, DR ;
SCOTT, MC .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (09) :929-943
[10]   INVIVO MEASUREMENTS OF BONE LEAD - A COMPARISON OF 2 X-RAY-FLUORESCENCE TECHNIQUES USED AT 3 DIFFERENT BONE SITES [J].
SOMERVAILLE, LJ ;
NILSSON, U ;
CHETTLE, DR ;
TELL, I ;
SCOTT, MC ;
SCHUTZ, A ;
MATTSSON, S ;
SKERFVING, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12) :1833-1845