DETERMINATION OF CISPLATIN AND SOME POSSIBLE METABOLITES BY ION-PAIRING CHROMATOGRAPHY WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION

被引:63
作者
ZHAO, Z
TEPPERMAN, K
DORSEY, JG
ELDER, RC
机构
[1] UNIV CINCINNATI, BIOMED CHEM RES CTR, DEPT CHEM, CINCINNATI, OH 45221 USA
[2] UNIV CINCINNATI, BIOMED CHEM RES CTR, DEPT BIOL SCI, CINCINNATI, OH 45221 USA
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1993年 / 615卷 / 01期
关键词
D O I
10.1016/0378-4347(93)80293-D
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive method is described for measuring cisplatin and some possible metabolites. The method combines reversed-phase ion-pairing liquid chromatography (LC) with inductively coupled plasma mass spectrometry (ICP-MS) for platinum-specific detection. Separation conditions for cisplatin hydrolysis products and the reaction products of cisplatin with methionine, cysteine, and glutathione have been investigated with sodium dodecylsulfate or heptanesulfonate as the ion-pairing agent. The detection limit for cisplatin was found to be 0.1 ng, corresponding to a concentration detection limit of 1 ng/ml when using an injection volume of 100 mul. This study has demonstrated the usefulness of LC-ICP-MS for cisplatin metabolism studies.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 28 条
[1]   EVALUATION OF INDUCTIVELY COUPLED MASS-SPECTROMETRY FOR THE DETERMINATION OF PLATINUM IN PLASMA [J].
ALLAIN, P ;
BERRE, S ;
MAURAS, Y ;
LEBOUIL, A .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (03) :141-143
[2]   DETERMINATION OF CISPLATIN AND RELATED PLATINUM COMPLEXES IN PLASMA ULTRAFILTRATE AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE RADIOACTIVITY DETECTION [J].
BALDEW, GS ;
VOLKERS, KJ ;
DEGOEIJ, JJM ;
VERMEULEN, NPE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 491 (01) :163-174
[3]   EVALUATION OF REDUCTIVE AMPEROMETRIC DETECTION IN THE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ANTI-NEOPLASTIC PLATINUM COMPLEXES [J].
BANNISTER, SJ ;
STERNSON, LA ;
REPTA, AJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 273 (02) :301-318
[4]  
CASETTA B, 1991, ATOM SPECTROSC, V12, P81
[5]   STABILITY OF CISPLATIN, IPROPLATIN, CARBOPLATIN, AND TETRAPLATIN IN COMMONLY USED INTRAVENOUS SOLUTIONS [J].
CHEUNG, YW ;
CRADOCK, JC ;
VISHNUVAJJALA, BR ;
FLORA, KP .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1987, 44 (01) :124-130
[6]   A STUDY OF THE PROTECTIVE EFFECT OF CHLORIDE SALTS ON CISPLATIN NEPHROTOXICITY [J].
DALEYYATES, PT ;
MCBRIEN, DCH .
BIOCHEMICAL PHARMACOLOGY, 1985, 34 (13) :2363-2369
[7]   CISPLATIN METABOLITES IN PLASMA, A STUDY OF THEIR PHARMACOKINETICS AND IMPORTANCE IN THE NEPHROTOXIC AND ANTITUMOUR ACTIVITY OF CISPLATIN [J].
DALEYYATES, PT ;
MCBRIEN, DCH .
BIOCHEMICAL PHARMACOLOGY, 1984, 33 (19) :3063-3070
[8]   ANALYSIS OF PLATINUM SPECIES ORIGINATING FROM CIS-DIAMMINEDICHLOROPLATINUM(II) (CISPLATIN) IN HUMAN AND RAT PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRIC DETECTION [J].
DEWAAL, WAJ ;
MAESSEN, FJMJ ;
KRAAK, JC .
JOURNAL OF CHROMATOGRAPHY, 1987, 407 :253-272
[9]   EFFICIENCY ENHANCEMENT IN MICELLAR LIQUID-CHROMATOGRAPHY [J].
DORSEY, JG ;
DEECHEGARAY, MT ;
LANDY, JS .
ANALYTICAL CHEMISTRY, 1983, 55 (06) :924-928
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF PLATINUM(II) IN PLASMA ULTRAFILTRATE AND URINE - COMPARISON WITH A FLAMELESS ATOMIC-ABSORPTION SPECTROMETRIC METHOD [J].
DRUMMER, OH ;
PROUDFOOT, A ;
HOWES, L ;
LOUIS, WJ .
CLINICA CHIMICA ACTA, 1984, 136 (01) :65-74