TITANIUM-INDUCED ARTHROPATHY ASSOCIATED WITH POLYETHYLENE-METAL SEPARATION AFTER TOTAL JOINT REPLACEMENT

被引:16
作者
QUALE, JL
MURPHEY, MD
HUNTRAKOON, M
RECKLING, FW
NEFF, JR
机构
[1] UNIV KANSAS,MED CTR,DEPT DIAGNOST RADIOL,39TH ST & RAINBOW BLVD,KANSAS CITY,KS 66103
[2] UNIV KANSAS,MED CTR,DEPT PATHOL,KANSAS CITY,KS 66103
[3] UNIV KANSAS,MED CTR,ORTHOPED SURG SECT,KANSAS CITY,KS 66103
关键词
HIP; PROSTHESES; KNEE;
D O I
10.1148/radiology.182.3.1535907
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Complications of total joint replacements are not infrequent. The authors describe five patients with displacement of the polyethylene component in two knee (metal-backed patellar component) and three hip joint replacements. Clinical, radiographic, surgical, and pathologic findings were reviewed in all cases. Conventional radiographs revealed abnormal position of the metal components in all patients and opaque curvilinear periarticular deposits in four. Arthropathy caused by deposition of small titanium particles from metal friction (in the absence of interposed polyethylene) was pathologically proved to correspond to the periarticular opacity. The subtle radiolucent polyethylene component was identified in all patients; adequate visualization in some cases may necessitate imaging with additional methods such as magnification, phosphor plate, and soft-tissue radiographic techniques; conventional tomography; and arthrography. Early recognition of these abnormalities in patients with painful joint replacements may allow less extensive surgical revision and prevent development of titanium-induced arthropathy.
引用
收藏
页码:855 / 858
页数:4
相关论文
共 19 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]  
Barone J G, 1989, N J Med, V86, P473
[3]   FAILURE OF THE METAL-BACKED PATELLAR COMPONENT AFTER TOTAL KNEE REPLACEMENT [J].
BAYLEY, JC ;
SCOTT, RD ;
EWALD, FC ;
HOLMES, GB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05) :668-674
[4]  
BAYLEY JC, 1988, CLIN ORTHOP RELAT R, V236, P82
[5]   METALLOSIS ASSOCIATED WITH A STABLE TITANIUM-ALLOY FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT - A CASE-REPORT [J].
BLACK, J ;
SHERK, H ;
BONINI, J ;
ROSTOKER, WR ;
SCHAJOWICZ, F ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (01) :126-130
[6]  
CLARK IC, 1975, CLIN ORTHOPAEDICS, V121, P126
[7]  
FREIBERGER RH, 1979, ARTHROGRAPHY, P189
[8]  
HABERMAN ET, 1986, SEMIN ROENTGENOL, V21, P1
[9]  
HALBRECHT J, 1989, B HOSP JOINT DIS ORT, V49, P48
[10]   COBALT TOXICITY AFTER MCKEE HIP ARTHROPLASTY [J].
JONES, DA ;
LUCAS, HK ;
ODRISCOLL, M ;
PRICE, CHG ;
WIBBERLEY, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1975, 57 (03) :289-296