INITIAL EXPERIENCES WITH A MINIATURIZED PRESSURE TRANSDUCER DURING CORONARY ANGIOPLASTY

被引:56
作者
EMANUELSSON, H [1 ]
DOHNAL, M [1 ]
LAMM, C [1 ]
TENERZ, L [1 ]
机构
[1] SAHLGRENS UNIV HOSP,DEPT RADIOL,S-41345 GOTHENBURG,SWEDEN
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1991年 / 24卷 / 02期
关键词
CORONARY ANGIOPLASTY; PRESSURE GRADIENT; BLOOD PRESSURE; FIBEROPTIC; GUIDEWIRE; PRESSURE TRANSDUCER;
D O I
10.1002/ccd.1810240213
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A newly constructed pressure sensor with a diameter of 0.45 mm was evaluated in 15 patients undergoing balloon coronary angioplasty (PTCA). The sensor and an optic fiber were mounted on a 0.018" guide wire, which was used in the balloon catheter. Pressure gradients were recorded before and after PTCA, respectively. The pressure tracings were of satisfactory quality in all cases. The mean systolic and diastolic gradients before PTCA were 32 +/- 20mm Hg and 44 +/- 26mm Hg, respectively. Pressure gradients were also obtained with the balloon placed in the lesion in order to simulate the conventional way of pressure measurement through the balloon catheter. In this setting, the systolic and diastolic gradients were 77 +/- 32mm Hg and 59 +/- 25mm Hg, respectively. Following balloon dilatation, the systolic pressure gradient decreased to 14 +/- 12mm Hg, and the diastolic gradient to 13 +/- 11mm Hg. In conclusion, this new pressure sensor delivers recordings of good quality and may be especially of interest during angioplasty due to its small diameter.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 23 条
  • [1] MEASUREMENT OF TRANSSTENOTIC PRESSURE-GRADIENT DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    ANDERSON, HV
    ROUBIN, GS
    LEIMGRUBER, PP
    COX, WR
    DOUGLAS, JS
    KING, SB
    GRUENTZIG, AR
    [J]. CIRCULATION, 1986, 73 (06) : 1223 - 1230
  • [2] CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS
    ARNETT, EN
    ISNER, JM
    REDWOOD, DR
    KENT, KM
    BAKER, WP
    ACKERSTEIN, H
    ROBERTS, WC
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) : 350 - 356
  • [3] CHAW H, 1987, 4TH INT C SOL STAT S, P344
  • [4] VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS
    DEROUEN, TA
    MURRAY, JA
    OWEN, W
    [J]. CIRCULATION, 1977, 55 (02) : 324 - 328
  • [5] OBSERVER AGREEMENT IN EVALUATING CORONARY ANGIOGRAMS
    DETRE, KM
    WRIGHT, E
    MURPHY, ML
    TAKARO, T
    [J]. CIRCULATION, 1975, 52 (06) : 979 - 986
  • [6] FORMAN A, 1979, J MED ENG TECHNOL, V3, P9
  • [7] USEFULNESS OF TRANSSTENOTIC CORONARY PRESSURE-GRADIENT MEASUREMENTS DURING DIAGNOSTIC CATHETERIZATION
    GANZ, P
    ABBEN, R
    FRIEDMAN, PL
    GARNIC, JD
    BARRY, WH
    LEVIN, DC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (08) : 910 - 914
  • [8] GRONDIN CM, 1974, CIRCULATION, V49, P703
  • [9] IMPLICATION OF TRANSSTENOTIC CORONARY PRESSURE-GRADIENT MEASUREMENT DURING CORONARY ANGIOPLASTY
    HARAPHONGSE, M
    TYMCHAK, W
    BURTON, JR
    ROSSALL, RE
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1986, 12 (02): : 80 - 84
  • [10] MAXIMAL CORONARY FLOW AND THE CONCEPT OF CORONARY VASCULAR RESERVE
    HOFFMAN, JIE
    [J]. CIRCULATION, 1984, 70 (02) : 153 - 159