COAXIAL PERCUTANEOUS BIOPSY TECHNIQUE WITH AUTOMATED BIOPSY DEVICES - VALUE IN IMPROVING ACCURACY AND NEGATIVE PREDICTIVE VALUE

被引:123
作者
MOULTON, JS
MOORE, PT
机构
[1] Department of Radiology, St Anthony Hospital, Denver, CO 80204
关键词
BIOPSIES; BONES; BIOPSY; COMPUTED TOMOGRAPHIC (CT) GUIDANCE; KIDNEY; LIVER; PANCREAS; PERITONEUM; RETROPERITONEAL SPACE; THORAX;
D O I
10.1148/radiology.186.2.8421758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three hundred percutaneous biopsies were performed in 267 consecutive patients by means of a coaxial technique with use of 18- and 20-gauge automated cutting biopsy devices and 22-gauge aspiration needles. Thoracic, hepatic, renal, pancreatic, adrenal, splenic, retroperitoneal, and musculoskeletal soft-tissue masses were sampled. For malignant masses (229 cases), the sensitivity was 79% for cytologic analysis, 88% for histologic analysis, and 92% for both combined. In benign disease (71 cases), a correct specific diagnosis was made with cytologic analysis in 38%, with histologic analysis in 97%, and with both combined in 97%. The negative predictive value was 60% for cytologic analysis, 72% for histologic analysis, and 80% for both combined. When only cancer-negative results in which a specific benign diagnosis was made were considered, the negative predictive value was 100% for cytologic analysis, 97% for histologic analysis, and 97% for both combined. The positive predictive value was 100% for both cytologic and histologic analysis. Bleeding complications occurred in 3% of biopsies, including in one patient who died.
引用
收藏
页码:515 / 522
页数:8
相关论文
共 24 条
  • [1] BIOPSY NEEDLE CHARACTERISTICS ASSESSED IN THE LABORATORY
    ANDRIOLE, JG
    HAAGA, JR
    ADAMS, RB
    NUNEZ, C
    [J]. RADIOLOGY, 1983, 148 (03) : 659 - 662
  • [2] AUTOMATED BIOPSY DEVICES - SIGNIFICANCE AND SAFETY
    BERNARDINO, ME
    [J]. RADIOLOGY, 1990, 176 (03) : 615 - 616
  • [3] BERQUIST TH, 1980, MAYO CLIN PROC, V55, P475
  • [4] SHEATH NEEDLE FOR LIVER-BIOPSY IN HIGH-RISK PATIENTS
    CHUANG, VP
    ALSPAUGH, JP
    [J]. RADIOLOGY, 1988, 166 (01) : 261 - 262
  • [5] A TECHNIQUE FOR EMBOLIZATION OF BIOPSY TRACTS
    CRUMMY, AB
    MCDERMOTT, JC
    WOJTOWYCZ, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (01) : 67 - 68
  • [6] BIOPSY OF THE PANCREAS WITH A BIOPSY GUN
    ELVIN, A
    ANDERSSON, T
    SCHEIBENPFLUG, L
    LINDGREN, PG
    [J]. RADIOLOGY, 1990, 176 (03) : 677 - 679
  • [7] ERWIN BC, 1986, CANCER, V57, P1074, DOI 10.1002/1097-0142(19860301)57:5<1074::AID-CNCR2820570535>3.0.CO
  • [8] 2-E
  • [9] CT-GUIDED ASPIRATION BIOPSY OF THE THORAX
    FINK, I
    GAMSU, G
    HARTER, LP
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (05) : 958 - 962
  • [10] POWERED CUTTING NEEDLE-BIOPSY OF THE PLEURA AND CHEST WALL
    GLEESON, F
    LOMAS, DJ
    FLOWER, CDR
    STEWART, S
    [J]. CLINICAL RADIOLOGY, 1990, 41 (03) : 199 - 200