TRACKING OF SINGLE FLUORESCENT PARTICLES IN 3 DIMENSIONS - USE OF CYLINDRICAL OPTICS TO ENCODE PARTICLE POSITION

被引:307
作者
KAO, HP
VERKMAN, AS
机构
[1] UNIV CALIF SAN FRANCISCO, CARDIOVASC RES INST, DEPT MED, SAN FRANCISCO, CA 94143 USA
[2] UNIV CALIF SAN FRANCISCO, CARDIOVASC RES INST, DEPT PHYSIOL, SAN FRANCISCO, CA 94143 USA
[3] UNIV CALIF SAN FRANCISCO, BIOENGN GRAD GRP, SAN FRANCISCO, CA 94143 USA
关键词
D O I
10.1016/S0006-3495(94)80601-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a novel optical technique for three-dimensional tracking of single fluorescent particles using a modified epifluorescence microscope containing a weak cylindrical lens in the detection optics and a microstepper-controlled fine focus. Images of small, fluorescent particles were circular in focus but ellipsoidal above and below focus; the major axis of the ellipsoid shifted by 90 degrees in going through focus. Particle z position was determined from the image shape and orientation by applying a peak detection algorithm to image projections along the x and y axes; x, y position was determined from the centroid of the particle image. Typical spatial resolution was 12 nm along the optical axis and 5 nm in the image plane with a maximum sampling rate of 3-4 Hz. The method was applied to track fluorescent particles in artificial solutions and living cells. In a solution of viscosity 30 cP, the mean squared distance (MSD) traveled by a 264 nm diameter rhodamine-labeled bead was linear with time to 20 s. The measured diffusion coefficient, 0.0558 +/- 0.001 mu m(2)/s (SE, n = 4), agreed with the theoretical value of 0.0556 mu m(2)/s. Statistical variability of MSD curves for a freely diffusing bead was in quantitative agreement with Monte Carte simulations of three-dimensional random walks. In a porous glass matrix, the MSD data was curvilinear and showed reduced bead diffusion. In cytoplasm of Swiss 3T3 fibroblasts, bead diffusion was restricted. The water permeability in individual Chinese Hamster Ovary cells was measured from the z movement of a fluorescent bead fixed at the cell surface in response osmotic gradients; water permeability was increased by >threefold in cells expressing CHIP28 water channels. The simplicity and precision of this tracking method may be useful to quantify the complex trajectories of fluorescent particles in living cells.
引用
收藏
页码:1291 / 1300
页数:10
相关论文
共 21 条
[1]  
COUCH LW, 1987, DIGITAL ANALOG COMMU, P430
[2]   DETECTION OF GOLD PROBES WITH VIDEO-ENHANCED CONTRAST MICROSCOPY - NANOVID MICROSCOPY [J].
DEBRABANDER, M ;
GEERTS, H ;
NUYDENS, R ;
NUYENS, R .
AMERICAN JOURNAL OF ANATOMY, 1989, 185 (2-3) :282-295
[3]   NANOVID TRACKING - A NEW AUTOMATIC METHOD FOR THE STUDY OF MOBILITY IN LIVING CELLS BASED ON COLLOIDAL GOLD AND VIDEO MICROSCOPY [J].
GEERTS, H ;
DEBRABANDER, M ;
NUYDENS, R ;
GEUENS, S ;
MOEREMANS, M ;
DEMEY, J ;
HOLLENBECK, P .
BIOPHYSICAL JOURNAL, 1987, 52 (05) :775-782
[4]   TRACKING KINESIN-DRIVEN MOVEMENTS WITH NANOMETRE-SCALE PRECISION [J].
GELLES, J ;
SCHNAPP, BJ ;
SHEETZ, MP .
NATURE, 1988, 331 (6155) :450-453
[5]  
GIBSON SF, 1991, J OPT SOC AM A, V8, P1601, DOI 10.1364/JOSAA.8.001601
[6]  
GONZALEZ RC, 1987, DIGITAL IMAGE PROCES, P334
[7]  
GROSS DJ, 1988, SPECTROSCOPIC MEMBRA, V2, P19
[8]   DETERMINATION OF 3-DIMENSIONAL IMAGING PROPERTIES OF A LIGHT-MICROSCOPE SYSTEM - PARTIAL CONFOCAL BEHAVIOR IN EPIFLUORESCENCE MICROSCOPY [J].
HIRAOKA, Y ;
SEDAT, JW ;
AGARD, DA .
BIOPHYSICAL JOURNAL, 1990, 57 (02) :325-333
[9]  
INOUE S, 1986, VIDEO MICROSCOPY, P334
[10]  
JAMES ML, 1985, APPLIED NUMERICAL ME, P396