APPLICATION OF A DECONVOLUTION METHOD TO PLASMA EMITTED SPECTRA

被引:11
作者
DEPIESSE, M
BIRAUD, Y
LESAGE, A
RICHOU, J
机构
[1] OBSERV MEUDON,DESPA,F-92195 MEUDON,FRANCE
[2] OBSERV PARIS,DASGAL,PLASMA PHYS LAB,F-92195 MEUDON,FRANCE
关键词
D O I
10.1016/0022-4073(95)00014-C
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A non-linear deconvolution method called Biraud's method is presented. Using shapes of positive spectra, performances and limits are tested by numerical experiments. Results show that this treatment is adapted to restore noisy spectral line parameters with most apparatus functions. Comparing with other non-linear methods, we find an improvement on reconstructed profiles. Application to plasma emitted spectra leads to accurate line parameters restoration even with significant noise levels.