ONLINE DILUTION, STEADY-STATE CONCENTRATIONS BY TANDEM INJECTION AND MERGING STREAM - APPLICATION TO INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY SEQUENTIAL MULTIELEMENT SOIL ANALYSIS

被引:10
作者
ISRAEL, Y
BARNES, RM
机构
[1] Department of Chemistry, Lederle Graduate Research Center, University of Massachusetts, Amherst
关键词
Flow injection; Inductively coupled plasma atomic emission spectrometry; On-line dilution; Soil analysis;
D O I
10.1039/an9901501411
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently developed flow injection on-line dilution methods, i.e., the merging stream and tandem injection, which yield steady-state concentrations, have been applied to the analysis of reference soil sample digests by inductively coupled plasma atomic emission spectrometry. Direct or on-line dilution determinations were applied, with dilutions ranging from 1.8 to 15 for both dilution methods. Higher dilutions are not feasible, especially when trace elements are involved. A variable speed peristaltic pump was used to limit the total flow-rate by the merging-stream dilution method to 2 ml min-1. This permitted the design of a flow module with one set of coils and a flow configuration suitable for all dilutions. Varying the dilution required only the variation of the peristaltic pump flow tube diameters. Selecting the required dilution for the tandem injection method was carried out with no manual operations and involved only pre-programming of the injection time and the injection cycle period. The results obtained exhibit comparable accuracy and precision for major and minor elements to those obtained by direct determination. By varying the dilution for the determination of trace elements, screening the optimum dilution(s) suitable for the determination of each trace element is possible.
引用
收藏
页码:1411 / 1417
页数:7
相关论文
共 16 条
[1]  
BARNES RM, 1989, 26 C SPECTR INT SOF
[2]   APPLICATION OF AN ARGON-NITROGEN INDUCTIVELY-COUPLED RADIOFREQUENCY PLASMA (ICP) TO THE ANALYSIS OF GEOLOGICAL AND RELATED MATERIALS FOR THEIR RARE-EARTH CONTENTS [J].
BRENNER, IB ;
WATSON, AE ;
STEELE, TW ;
JONES, EA ;
GONCALVES, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (08) :785-797
[3]   SEPARATION OF YTTRIUM AND RARE-EARTH ELEMENTS FROM GEOLOGICAL-MATERIALS [J].
BROEKAERT, JAC ;
HORMANN, K .
ANALYTICA CHIMICA ACTA, 1981, 124 (02) :421-425
[4]   FLOW MANIFOLD FOR AUTOMATED ONLINE DILUTION OF STANDARDS FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY AND ITS USE IN A NULL MEASUREMENT METHOD [J].
BYSOUTH, SR ;
TYSON, JF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (02) :217-220
[5]   EXTENSIVE FLOW-INJECTION DILUTION FOR IN-LINE SAMPLE PRETREATMENT - COMPARISON BETWEEN SINGLE-STAGE AND DUAL-STAGE MODULES [J].
GARN, MB ;
GISIN, M ;
GROSS, H ;
KING, P ;
SCHMIDT, W ;
THOMMEN, C .
ANALYTICA CHIMICA ACTA, 1988, 207 (1-2) :225-231
[6]   HYDRODYNAMICALLY LIMITED PRECISION OF GRADIENT TECHNIQUES IN FLOW-INJECTION ANALYSIS [J].
GISIN, M ;
THOMMEN, C ;
MANSFIELD, KF .
ANALYTICA CHIMICA ACTA, 1986, 179 :149-167
[7]   1988 COMPILATION OF ELEMENTAL CONCENTRATION DATA FOR CCRMP SOILS SO-1 TO SO-4 [J].
GLADNEY, ES ;
ROELANDTS, I .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1989, 13 (02) :217-268
[8]  
HAHN RB, 1961, TREATISE ANAL CHEM 2, V5, P78
[9]  
ISRAEL Y, 1988, ANAL CHIM ACTA, V206, P313
[10]   ONLINE DILUTION, STEADY-STATE CONCENTRATIONS FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION AND MASS-SPECTROMETRY ACHIEVED BY TANDEM INJECTION AND MERGING-STREAM FLOW-INJECTION [J].
ISRAEL, Y ;
LASZTITY, A ;
BARNES, RM .
ANALYST, 1989, 114 (10) :1259-1265