THIN-FILM CLARK-TYPE OXYGEN SENSOR-BASED ON NOVEL POLYMER MEMBRANE SYSTEMS FOR IN-VIVO AND BIOSENSOR APPLICATIONS

被引:48
作者
JOBST, G
URBAN, G
JACHIMOWICZ, A
KOHL, F
TILADO, O
LETTENBICHLER, I
NAUER, G
机构
[1] VIENNA TECH UNIV,INST ALLEMEINE ELEKTROTECH & ELEKTR,A-1040 VIENNA,AUSTRIA
[2] UNIV VIENNA,INST PHYS CHEM,A-1090 VIENNA,AUSTRIA
关键词
THIN-FILM CLARK-TYPE OXYGEN SENSOR; ROSS PRINCIPLE; PHOTOSTRUCTURABLE MEMBRANES; SOLID ELECTROLYTE; HYDROGELS; INTERNAL OXYGEN RECYCLING;
D O I
10.1016/0956-5663(93)85024-I
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A planar miniaturized Clark-type oxygen sensor based on the Ross principle has been produced by means of thin-film technology. The use of a polarizable counter electrode in a three-electrode configuration allows the regeneration of the cathodically consumed oxygen, resulting in a zero-flux amperometric oxygen sensor. The platinum working and counter electrodes and the Ag/AgCl reference electrode were covered with a photostructured hydrogel layer, forming the electrolyte compartment, and a photostructured hydrophobic gas-permeable membrane. This arrangement exhibits no oxygen consumption and therefore the signal of the sensor shows almost no flow dependence. Additionally, this electrochemical feature leads to a dynamic equilibrium of the reaction products in the hydrogel layer, overcoming the lifetime limitations caused by buffer degradation in the classical Clark principle. The sensor was tested in buffer solutions and bovine serum, showing excellent performance and no effects of fouling on sensor response. This device can be scaled down and is best suited for integration with other sensors and as a basic transducer for biosensors.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 17 条
[1]  
ALTHOFF M, 1985, INT J MICROCIRC, V4, P379
[2]  
Baumgartl H, 1983, POLAROGRAPHIC OXYGEN, P37, DOI [10.1007/978-3-642-81863-9_4, DOI 10.1007/978-3-642-81863-9_4]
[3]   PROBLEMS ASSOCIATED WITH THE MINIATURIZATION OF A VOLTAMMETRIC OXYGEN SENSOR - CHEMICAL CROSSTALK AMONG ELECTRODES [J].
CHA, CS ;
SHAO, MJ ;
LIU, CC .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 2 (04) :239-242
[4]  
Fleckenstein W, 1984, FOCUS MHL, V1, P74
[5]   DIFFUSIVE PERMEABILITY OF SOLUTES IN POLYVINYL-ALCOHOL) MEMBRANES AS A FUNCTION OF THE DEGREE OF HYDRATION [J].
KOJIMA, Y ;
FURUHATA, K ;
MIYASAKA, K .
JOURNAL OF APPLIED POLYMER SCIENCE, 1984, 29 (02) :533-546
[6]   PERFORMANCE-CHARACTERISTICS OF A PLANAR CLARK-TYPE OXYGEN SENSOR [J].
KOUDELKA, M .
SENSORS AND ACTUATORS, 1986, 9 (03) :249-258
[7]   COMPARISON OF MICROBIAL SENSORS BASED ON AMPEROMETRIC AND POTENTIOMETRIC ELECTRODES [J].
MASCINI, M ;
MEMOLI, A .
ANALYTICA CHIMICA ACTA, 1986, 182 :113-122
[8]   A TELEMETRY-INSTRUMENTATION SYSTEM FOR CHRONICALLY IMPLANTED GLUCOSE AND OXYGEN SENSORS [J].
MCKEAN, BD ;
GOUGH, DA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (07) :526-532
[9]   ENZYME ELECTRODE FOR L-AMINO-ACIDS AND GLUCOSE [J].
NANJO, M ;
GUILBAULT, GG .
ANALYTICA CHIMICA ACTA, 1974, 73 (02) :367-373
[10]  
Ross J.J.W., 1966, U.S. Patent, Patent No. [3,260,656, 3260656]