MELT PELLETIZATION IN A HIGH-SHEAR MIXER .5. EFFECTS OF APPARATUS VARIABLES

被引:35
作者
SCHAEFER, T
TAAGEGAARD, B
THOMSEN, LJ
KRISTENSEN, HG
机构
[1] Royal Danish School of Pharmacy, Department of Pharmaceutics, Copenhagen
关键词
POLYETHYLENE GLYCOLS; PELLETS; MELT PELLETIZATION; MELT GRANULATION; HIGH SHEAR MIXER;
D O I
10.1016/0928-0987(93)90003-S
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Effects of two different sets of impeller blades on melt pelletization of lactose with polyethylene glycol (PEG) 3000 were investigated in an 8 litre high shear mixer. Results obtained in the 8 litre mixer were compared with previous results from a 50 litre high shear mixer of the same type. in the 8 litre mixer curved impeller blades were found to give rise to a high power input and smooth pellets of a spherical shape, whereas plane impeller blades caused a lower power input and irregular agglomerates. Agglomerate growth was found to be different in mixers of different scale. This difference was primarily ascribed to differences in movement of the mass, power input and product temperature.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 13 条
[1]   THE CONTROL OF DRUG RELEASE FROM CONVENTIONAL MELT GRANULATION MATRICES [J].
FLANDERS, P ;
DYER, GA ;
JORDAN, D .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1987, 13 (06) :1001-1022
[2]  
FORD JL, 1980, PHARM ACTA HELV, V55, P1
[3]  
KINGET R, 1985, Acta Pharmaceutica Technologica, V31, P57
[4]   THE EVALUATION OF FORMULATION AND PROCESSING CONDITIONS OF A MELT GRANULATION PROCESS [J].
MCTAGGART, CM ;
GANLEY, JA ;
SICKMUELLER, A ;
WALKER, SE .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1984, 19 (02) :139-148
[5]   FORMULATION AND EVALUATION OF PARACETAMOL 500 MG TABLETS PRODUCED BY A NEW DIRECT GRANULATION METHOD [J].
RUBINSTEIN, MH ;
MUSIKABHUMMA, P .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1980, 6 (05) :451-473
[6]  
SCHAEFER T, 1992, ACTA PHARM NORDICA, V4, P133
[7]  
SCHAEFER T, 1992, ACTA PHARM NORDICA, V4, P141
[8]  
SCHAEFER T, 1992, ACTA PHARM NORDICA, V4, P245
[9]   MELT PELLETIZATION IN A HIGH-SHEAR MIXER .4. EFFECTS OF PROCESS VARIABLES IN A LABORATORY-SCALE MIXER [J].
SCHAEFER, T ;
TAAGEGAARD, B ;
THOMSEN, LJ ;
KRISTENSEN, HG .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 1993, 1 (03) :125-131
[10]   MELT GRANULATION IN A LABORATORY SCALE HIGH SHEAR MIXER [J].
SCHAEFER, T ;
HOLM, P ;
KRISTENSEN, HG .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1990, 16 (08) :1249-1277