FURTHER INFORMATION ON THE USE OF PARA-NITROPHENYL PHOSPHATE TO QUANTITATE ACID-PHOSPHATASE ON VAGINAL SWABS EXAMINED IN CASES OF SEXUAL ASSAULT

被引:10
作者
ALLARD, J
DAVIES, A
机构
[1] The Metropolitan Police Forensic Science Laboratory, London SE1, Lambeth Road
关键词
D O I
10.1177/002580247901900305
中图分类号
D9 [法律]; DF [法律];
学科分类号
0301 ;
摘要
A simple test for screening swabs for the presence of semen has now been used on over 1000 vaginal swabs. The preliminary conclusions reached in a previous paper (Davies, 1978) are discussed and these have subsequently been shown to be correct: however, more information is now available. Despite the limitations of the method, the results can give a clear indication of the presence of semen. The test also continues to be of use on some occasions when the time interval between sexual intercourse and the swab being taken is contentious. Some modifications to the method arc also described. © 1979, The British Academy of Forensic Sciences. All rights reserved.
引用
收藏
页码:170 / 172
页数:3
相关论文
共 3 条
[1]   PHOSPHATASES IN BODY FLUIDS - DIFFERENTIATION OF SEMEN AND VAGINAL SECRETION [J].
ADAMS, EG ;
WRAXALL, BG .
FORENSIC SCIENCE, 1974, 3 (01) :57-62
[3]  
Kind S.S., 1964, METHODS FORENSIC SCI, P267