SURGICAL TECHNIQUES FOR REPOSITIONING A DISLOCATED INTRAOCULAR-LENS, REPAIR OF IRIDODIALYSIS, AND SECONDARY INTRAOCULAR-LENS IMPLANTATION USING INNOVATIVE 25-GAUGE FORCEPS

被引:29
作者
CHANG, S [1 ]
COLL, GE [1 ]
机构
[1] CORNELL UNIV,COLL MED,NEW YORK HOSP,DEPT OPHTHALMOL,NEW YORK,NY
关键词
D O I
10.1016/S0002-9394(14)73869-3
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE: We developed surgical techniques for the sulcus fixation of a posteriorly dislocated or secondarily implanted posterior chamber intraocular lens, repair of an iridodialysis, and the management of a decentered intraocular lens during vitreous surgery using innovative 25 gauge forceps. METHODS: The 25 gauge forceps have a curved shaft, a tip with a distal platform for grasping a suture, and a proximal groove for gripping a haptic. The forceps are inserted through a grooved scleral incision into the plane of the ciliary sulcus, facilitating manipulations such as fastening a suture loop around a haptic, repositing an intraocular lens at the ciliary sulcus, and grasping sutures during repair of a iridodialysis or implantation of a secondary intraocular lens. Seven patients underwent vitreous surgery using the new forceps. RESULTS: In all seven patients the surgical objectives were accomplished with the 25 gauge forceps without postoperative complications such as hemorrhage, hypotony, or lens decentration. CONCLUSIONS: The 25-gauge forceps are innovative instrumentation designed specifically for anterior segment applications during vitreous surgery.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 19 条
[1]
SIMPLIFIED TECHNIQUE FOR SUTURING DISLOCATED POSTERIOR CHAMBER INTRAOCULAR-LENS TO THE CILIARY SULCUS [J].
ANAND, R ;
BOWMAN, RW .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (09) :1205-1206
[2]
BLODI BA, 1992, OPHTHALMOLOGY, V99, P41
[3]
BLOOM SM, 1990, OPHTHALMIC SURG LAS, V21, P851
[4]
CORNEAL AUTOGRAFTS FOR EXTERNAL KNOTS IN TRANSSCLERALLY SUTURED POSTERIOR CHAMBER LENSES [J].
BUCCI, FA ;
HOLLAND, EJ ;
LINDSTROM, RL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 112 (03) :353-354
[5]
PARS-PLANA VITRECTOMY IN THE MANAGEMENT OF DISLOCATED POSTERIOR CHAMBER LENSES [J].
CAMPO, RV ;
CHUNG, KD ;
OYAKAWA, RT .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (05) :529-534
[6]
COMPARISON OF INTRAOCULAR-LENS FIXATION TECHNIQUES PERFORMED DURING PENETRATING KERATOPLASTY [J].
DAVIS, RM ;
BEST, D ;
GILBERT, GE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (06) :743-749
[7]
ANATOMIC STUDY OF TRANSSCLERALLY SUTURED INTRAOCULAR-LENS IMPLANTATION [J].
DUFFEY, RJ ;
HOLLAND, EJ ;
AGAPITOS, PJ ;
LINDSTROM, RL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (03) :300-309
[8]
MANAGEMENT OF DISLOCATED NUCLEAR FRAGMENTS AFTER PHACOEMULSIFICATION [J].
FASTENBERG, DM ;
SCHWARTZ, PL ;
SHAKIN, JL ;
GOLUB, BM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 112 (05) :535-539
[9]
A NEW TECHNIQUE FOR REPOSITIONING AND FIXATING A DISLOCATED INTRAOCULAR-LENS [J].
FRIEDBERG, MA ;
PILKERTON, AR .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (03) :413-415
[10]
GILLILAND GD, 1992, OPHTHALMOLOGY, V99, P1263