CHARACTERIZATION OF HOLLOW FIBER HEMODIALYSIS MEMBRANES - PORE-SIZE DISTRIBUTION AND PERFORMANCE

被引:18
作者
BROEK, AP
TEUNIS, HA
BARGEMAN, D
SPRENGERS, ED
SMOLDERS, CA
机构
[1] University of Twente, Dept. of Chemical Technology, 7500 AE Enschede
关键词
ARTIFICIAL KIDNEY; DIALYSIS; INCLUDING DONNAN; MEMBRANE PREPARATION AND STRUCTURE; MEMBRANE CHARACTERIZATION; THERMOPOROMETRY;
D O I
10.1016/0376-7388(92)80124-3
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of two commonly used sterilization methods for artificial kidneys on the morphology and performance of hollow fiber Hemophan(R) hemodialysis membranes was studied. A relatively new membrane characterization method, thermoporometry, was used to determine the pore size distributions and porosities of the differently treated membrane samples. The samples used for this study were not treated with a concentrated glycerol solution before sterilization. Hemophan was found to have a pore size distribution with pore radii between 1.5 and 12 nm, the volume porosity was 20%. The sample sterilized with ethylene oxide (EtO) had a volume porosity of 18% which was due to a decrease of the pore volume of the smallest pores. The applied dry steam sterilization treatment resulted in a drastic collapse of the large pores while smaller pores were formed. The calculated porosity was only 10%. The 'tortuous capillary pore model' was used to predict the performance of the artificial kidneys from the pore size distribution in the membrane material. In vitro dialysis experiments with creatinine and vitamin B12 were carried out to compare the calculated and measured clearance rates. Also the ultrafiltration capacity of the devices was determined. It was found that a reasonable estimation of the ultrafiltration capacity could be made. The calculated clearance rates were systematically underestimated, although the relative dependence of the clearance rates on the applied sterilization methods was approximated reasonably.
引用
收藏
页码:143 / 152
页数:10
相关论文
共 20 条
[1]   CHARACTERIZATION OF HEMOPHAN HEMODIALYSIS MEMBRANES BY THERMOPOROMETRY [J].
BROEK, AP ;
BARGEMAN, D ;
SPRENGERS, ED ;
SMOLDERS, CA .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (01) :25-28
[2]   NEW METHOD FOR SIMULTANEOUS DETERMINATION OF SIZE AND SHAPE OF PORES - THERMOPOROMETRY [J].
BRUN, M ;
LALLEMAND, A ;
QUINSON, JF ;
EYRAUD, C .
THERMOCHIMICA ACTA, 1977, 21 (01) :59-88
[3]  
COLTON C K, 1971, Journal of Biomedical Materials Research, V5, P459, DOI 10.1002/jbm.820050504
[4]  
COLTON CK, 1981, KIDNEY, V2, P2425
[5]   CHARACTERIZATION OF UF MEMBRANES - MEMBRANE-CHARACTERISTICS AND CHARACTERIZATION TECHNIQUES [J].
CUPERUS, FP ;
SMOLDERS, CA .
ADVANCES IN COLLOID AND INTERFACE SCIENCE, 1991, 34 :135-173
[6]   CHARACTERIZATION OF CLEAN AND FOULED ULTRAFILTRATION MEMBRANES [J].
HANEMAAIJER, JH ;
ROBBERTSEN, T ;
VANDENBOOMGAARD, T ;
OLIEMAN, C ;
BOTH, P ;
SCHMIDT, DG .
DESALINATION, 1988, 68 (2-3) :93-108
[7]  
HIGUCHI A, 1984, POLYM BULL, V11, P203
[8]  
Kim SW., 1980, ACS S SER, V127, P347, DOI [10.1021/bk-1980-0127.ch020, DOI 10.1021/BK-1980-0127.CH020]
[9]  
KLEIN E, 1979, J MEMBRANE SCI, V5, P173, DOI 10.1016/S0376-7388(00)80446-9
[10]   DIFFUSIVE AND HYDRAULIC PERMEABILITIES OF COMMERCIALLY AVAILABLE CELLULOSIC HEMODIALYSIS FILMS AND HOLLOW FIBERS [J].
KLEIN, E ;
HOLLAND, FF ;
DONNAUD, A ;
LEBEOUF, A ;
EBERLE, K .
JOURNAL OF MEMBRANE SCIENCE, 1977, 2 (04) :349-364