A HIGH-PRESSURE TRIAXIAL CELL WITH IMPROVED MEASUREMENT SENSITIVITY FOR SATURATED WATER PERMEABILITY OF HIGH-PERFORMANCE CONCRETE

被引:38
作者
ELDIEB, AS
HOOTON, RD
机构
[1] Ph.D. Candidate, Department of Civil Engineering, University of Toronto
[2] Department of Civil Engineering, University of Toronto
关键词
D O I
10.1016/0008-8846(94)90005-1
中图分类号
TU [建筑科学];
学科分类号
0813 [建筑学];
摘要
The measurement of the saturated water permeability of concrete is of great interest, but with the rapid improvements in properties of high performance concretes, the most common problem is the ability and accuracy of measuring the very small flow volumes. A high pressure triaxial cell with improved measurement sensitivity, capable of continuously measuring saturated water permeability of the order of < 10(-15) m/s, is presented in this paper.
引用
收藏
页码:854 / 862
页数:9
相关论文
共 17 条
[1]
ANDERSON AJB, 1989, INTERPRETING DATA 1S
[2]
BAKER AF, 1985, CONCRETE, V19, P19
[3]
BAKKER RFM, 1983, ACI SP79, V1, P589
[4]
WATER PERMEABILITY OF CEMENT PASTE [J].
BANTHIA, N ;
MINDESS, S .
CEMENT AND CONCRETE RESEARCH, 1989, 19 (05) :727-736
[5]
COLLINS JF, 1985, CIVIL ENG PRACTISING, V5, P579
[6]
GLANVILLE WH, 1931, 3 DEP SCI IND RES BL
[7]
A SIMPLE PERMEAMETER FOR WATER OR GAS-FLOW [J].
HEARN, N ;
MILLS, RH .
CEMENT AND CONCRETE RESEARCH, 1991, 21 (2-3) :257-261
[8]
Hooton R. D, 1988, MATERIALS RES SOC S, V137, P141, DOI 10.1557/PROC-137-141
[9]
Hooton R. D., 1988, ADV CEMENT MANUFACTU, P143
[10]
Hooton R. D., 1988, MATERIALS RES SOC S, V137, P157, DOI [10.1557/PROC-137-157, DOI 10.1557/PROC-137-157]