MAGNETIC-RESONANCE-IMAGING OF BLOOD-VESSELS AT HIGH FIELDS - INVIVO AND INVITRO MEASUREMENTS AND IMAGE SIMULATION
被引:379
作者:
OGAWA, S
LEE, TM
机构:
[1] AT& T Bell Laboratories, Murray Hill, New Jersey
关键词:
D O I:
10.1002/mrm.1910160103
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Unusually high image contrast in vivo magnetic resonance imaging of the brain becomes observable at high magnetic fields when the blood oxygenation level is lowered. The cause of the contrast has been attributed to a magnetic susceptibility effect induced by paramagnetic deoxyhemoglobin in red cells. When the cylinder axis of a blood vessel is not parallel to the main magnetic field, the susceptibility difference produces varying local fields around the blood vessel. In gradient‐echo images, not in spin‐echo images, these local fields cause intravoxel dephasing of the water signal of the surrounding tissue. This description of the contrast enhancement has been confirmed by a series of in vitro blood sample experiments and image simulations. A predicted contrast change has been demonstrated in brain images of a mouse placed at two different orientations in the magnet. From the simulated images, the dependence of the contrast on the field strength has been estimated. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company