HIGH-ACCURACY DISTANCE MEASUREMENT BY 2-WAVELENGTH PULSED LASER SOURCES

被引:15
作者
QUERZOLA, B
机构
[1] Centro Informazioni Studi Esperienze, Segrate, Milano
来源
APPLIED OPTICS | 1979年 / 18卷 / 17期
关键词
D O I
10.1364/AO.18.003035
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The two-wavelength method, proposed by P. L. Bender and J. C. Owens, makes it possible to achieve fractional accuracies of better than 10−6 (1 ppm) in ranging. The technique has only been applied to continuous laser sources. This paper attempts to ascertain whether high power pulsed lasers can be successfully used with this method and to check the system feasibility from an experimental viewpoint. Instead of phase comparison techniques (typical of cw systems), the pulse sources involve direct transit time measurements. The consequent average of N measurements can reduce the error on the distance mean value by an N−1/2 factor. The main cause of error concerns threshold crossing in pulse discrimination, especially in the presence of amplitude fluctuations. Causes of error affecting such measurements are analyzed. Results are reported of measurements at distances of 5 km and 13 km by pulsed ruby laser PTM emission (λ = 6943 Å) and its second harmonic (λ = 3472 Å) using a timer with 20-psec accuracy. Such measurements show that two-wavelength pulsed laser telemeters can reach 1-ppm accuracies for distances exceeding a few kilometers: over large distances (greater than 50 km, under favorable visibility conditions), such high power pulsed telemeters appear to be the only ones to achieve this accuracy. © 1979 Optical Society of America.
引用
收藏
页码:3035 / 3047
页数:13
相关论文
共 37 条
[1]  
ALBERTIN A, 1972, ALTA FREQ, V41, P121
[2]   THE DISPERSION OF AIR BETWEEN 2500A AND 6500A [J].
BARRELL, H .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1951, 41 (05) :295-299
[3]  
Barrell H., 1939, PHIL T ROY SOC LOND, V238, P1
[4]   CORRECTION OF OPTICAL DISTANCE MEASUREMENTS FOR FLUCTUATING ATMOSPHERIC INDEX OF REFRACTION [J].
BENDER, PL ;
OWENS, JC .
JOURNAL OF GEOPHYSICAL RESEARCH, 1965, 70 (10) :2461-&
[5]  
BRADSELL RH, 1952, PRINCIPLES RADAR
[6]   PRECISE PTM CONTROL OF A RUBY LASER [J].
CHRISTMAS, TM ;
WILDEY, CG .
ELECTRONICS LETTERS, 1970, 6 (22) :696-+
[7]   EFFECTS OF PRECIPITATION ON PROPAGATION AT 0.63, 3.5, AND 10.6 MICRONS [J].
CHU, TS ;
HOGG, DC .
BELL SYSTEM TECHNICAL JOURNAL, 1968, 47 (05) :723-+
[8]  
COTTINI C, 1967, ENERG NUCL MILAN, V14, P705
[9]   2-LASER OPTICAL DISTANCE-MEASURING INSTRUMENT THAT CORRECTS FOR ATMOSPHERIC INDEX OF REFRACTION [J].
EARNSHAW, KB ;
HERNANDEZ, EN .
APPLIED OPTICS, 1972, 11 (04) :749-+
[10]   THE DISPERSION OF STANDARD AIR [J].
EDLEN, B .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (05) :339-344