MASS DISCRIMINATION DUE TO Z AXIS ION CLOUD COHERENCE IN THE FOURIER-TRANSFORM MASS-SPECTROMETRY TRAPPED-ION CELL

被引:21
作者
RIEGNER, DE [1 ]
HOFSTADLER, SA [1 ]
LAUDE, DA [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM,AUSTIN,TX 78712
关键词
D O I
10.1021/ac00003a014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mass discrimination effect common to Fourier transform mass spectrometry (FTMS) experiments involving the introduction of externally generated ions to the analyzer trapped-ion cell is described. The combination of inhomogeneous excitation fields with the coherent z axis motion of focused ion packets is shown to introduce time-dependent variations in apparent relative mass abundances that are as large as 60%. This effect is evaluated for the dual-cell ion equilibration experiment by modeling the z axis motion of isomass packets between adjacent trapped-ion cells during the pulse sequence. Predicted oscillations in the FTMS signal profile with period equal to half the expected cubic cell trapping period are then verified experimentally. Mechanisms for abrupt termination of the mass-dependent oscillations at a time 2-25 ms after initiation are also considered; for example, ion-neutral and ion-ion interactions are discounted, and correlation with the onset of large amplitude magnetron motion is established. Finally, the merits of the dual-cell ion equilibration pulse sequence as a direct probe of z axis evolution of the ion cloud during the FTMS experiment are demonstrated.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 24 条
[1]   EJECTION OF LOW-MASS CHARGED-PARTICLES IN HIGH MAGNETIC-FIELD ICR SPECTROMETERS [J].
ALLEMANN, M ;
KOFEL, P ;
KELLERHALS, H ;
WANCZEK, KP .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 75 (01) :47-54
[2]  
ALLEMANN M, 1981, CHEM PHYS LETT, V84, P547, DOI 10.1016/0009-2614(81)80405-8
[3]   STORED WAVE-FORM SIMULTANEOUS MASS-SELECTIVE EJECTION EXCITATION FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, L ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 79 (01) :115-125
[4]  
CODY RB, 1985, ANAL CHIM ACTA, V178, P43
[5]   ZETA-AXIS OSCILLATION SIDEBANDS IN FT ICR MASS-SPECTRA [J].
DELONG, SE ;
MITCHELL, DW ;
CHERNIAK, DJ ;
HARRISON, TM .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 91 (03) :273-282
[6]   MAGNETRON MOTION OF IONS IN THE CUBICAL ICR CELL [J].
DUNBAR, RC ;
CHEN, JH ;
HAYS, JD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 57 (01) :39-56
[7]  
DUNBAR RC, 1985, INT J MASS SPECTROM, V56, P1
[8]   MASS DISCRIMINATION BASED ON LONGITUDINAL ION MOTION IN A DOUBLE-CELL FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
GIANCASPRO, C ;
VERDUN, FR .
ANALYTICAL CHEMISTRY, 1986, 58 (09) :2097-2099
[9]   AN EXPERIMENTAL-STUDY OF ION MOTIONS IN A DOUBLE CELL FT/ICR INSTRUMENT [J].
GIANCASPRO, C ;
VERDUN, FR ;
MULLER, JF .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 72 (1-2) :63-71
[10]   FIELD-CORRECTED ION CELL FOR ION-CYCLOTRON RESONANCE [J].
HANSON, CD ;
CASTRO, ME ;
KERLEY, EL ;
RUSSELL, DH .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :520-526