REDUCTION OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY ADDING NITROGEN TO THE PLASMA GAS

被引:37
作者
CRAIG, JM [1 ]
BEAUCHEMIN, D [1 ]
机构
[1] QUEENS UNIV,DEPT CHEM,KINGSTON K7L 3N6,ONTARIO,CANADA
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; MIXED-GAS PLASMA; EFFECT OF CONCOMITANT ELEMENTS;
D O I
10.1039/ja9920700937
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mixed-gas plasmas were produced in inductively coupled plasma mass spectrometry (ICP-MS) by adding 2-10% N2 to the plasma (outer) gas and keeping both the r.f. power and the nebulization efficiency (i.e., nebulizer flow rate and sample delivery rate) constant. The resulting ion sources were characterized (and compared with a conventional Ar plasma) in terms of sensitivity, mass discrimination and susceptibility to the effect of up to 0.1 mol dm-3 K, for several analytes (Al, V, Cr, Fe, Co, Ni, Cu, Zn, Se, Cd and Pb). Sensitivity decreased upon addition of N2 (consistent with a shift of the initial radiation zone away from the sampler) along with the signal-to-noise (S/N) and signal-to-background (S/B) ratios, except for those analytes suffering from interferences from Ar polyatomic species (Cr, Fe and Se) where N2 then improved S/N and S/B. The decrease in sensitivity was smaller for Cd, Zn and Se, as N2 probably improved the ionization of these elements (which are not 100% ionized in an Ar plasma). Mass discrimination was reduced in the m/z range 51-78. Finally, the effect of 0.01 mol dm-3 K was eliminated with 10% N2 in the m/z range 51-114. The amount of N2 could also be adjusted to eliminate the effect of 0.1 mol dm-3 K on a given analyte (but not for the whole mass range).
引用
收藏
页码:937 / 942
页数:6
相关论文
共 23 条
[1]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[2]   INVESTIGATIONS ON MIXED-GAS PLASMAS PRODUCED BY ADDING NITROGEN TO THE PLASMA GAS IN ICP-MS [J].
BEAUCHEMIN, D ;
CRAIG, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (05) :603-614
[3]  
BEAUCHEMIN D, 1990, PLASMA SOURCE MASS S, P25
[4]   DETERMINATION OF ARSENIC IN SAMPLES WITH HIGH CHLORIDE CONTENT BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BRANCH, S ;
EBDON, L ;
FORD, M ;
FOULKES, M ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :151-154
[5]  
DATE AR, 1989, APPLICATIONS INDUCTI
[6]  
DEAN JA, 1985, LANGES HDB CHEM
[7]   STUDY OF SOLIDS DEPOSITION ON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY SAMPLERS AND SKIMMERS [J].
DOUGLAS, DJ ;
KERR, LA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :749-752
[8]   SIMPLE APPROACH TO REDUCING POLYATOMIC ION INTERFERENCES ON ARSENIC AND SELENIUM IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EVANS, EH ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (03) :299-300
[9]   EFFECT OF ORGANIC-SOLVENTS AND MOLECULAR GASES ON POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EVANS, EH ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) :425-429
[10]   NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GILLSON, GR ;
DOUGLAS, DJ ;
FULFORD, JE ;
HALLIGAN, KW ;
TANNER, SD .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1472-1474