THE INFLUENCE OF INHALATION TECHNIQUE ON TECHNEGAS PARTICLE DEPOSITION AND IMAGE APPEARANCE IN NORMAL VOLUNTEERS

被引:1
作者
LLOYD, JJ [1 ]
JAMES, JM [1 ]
SHIELDS, RA [1 ]
TESTA, HJ [1 ]
机构
[1] MANCHESTER ROYAL INFIRM,DEPT NUCL MED,MANCHESTER M13 9WL,LANCS,ENGLAND
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1994年 / 21卷 / 05期
关键词
TECHNEGAS; VENTILATION; AEROSOL; DEPOSITION; BREATHING PATTERN;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this work was to investigate the influence of inhalation technique on Technegas image quality and on fractional particle deposition. This was investigated in six normal volunteers using three different types of breathing pattern. Fractional deposition was determined by analysis of dynamic gamma camera images acquired during Technegas administration. Static lung images were subsequently acquired and assessed independently by three experienced observers. High-quality images were obtained in all cases although slight differences were noted. The images produced using a slow deep inspiration with a breath hold (i.e. the standard method) were of more uniform texture and also had the least gradient in activity from apex to base. The converse was true for a rapid inhalation technique. The average fractional deposition per breath was 55%, but this varied between individuals and with breathing pattern, being most influenced by the total duration of a breath. We conclude that for patient studies the standard inhalation technique is best, although variation to suit individual patients would be acceptable. These results contrast with similar studies using conventional radio-aerosols, which tend to show a greater sensitivity of image appearance to changes in breathing pattern and lower fractional depositions.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 14 条
[1]  
AGNEW JE, 1984, AEROSOLS LUNG, P92
[2]   HUMAN VARIATION IN THE PERIPHERAL AIR-SPACE DEPOSITION OF INHALED PARTICLES [J].
BENNETT, WD ;
SMALDONE, GC .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (04) :1603-1610
[3]   TECHNEGAS - A NEW VENTILATION AGENT FOR LUNG-SCANNING [J].
BURCH, WM ;
SULLIVAN, PJ ;
MCLAREN, CJ .
NUCLEAR MEDICINE COMMUNICATIONS, 1986, 7 (12) :865-&
[4]   FACTORS INFLUENCING THE REGIONAL DEPOSITION OF INHALED PARTICLES IN MAN [J].
CHAMBERLAIN, MJ ;
MORGAN, WKC ;
VINITSKI, S .
CLINICAL SCIENCE, 1983, 64 (01) :69-78
[5]   TECHNEGAS FOR INHALATION LUNG IMAGING [J].
ISAWA, T ;
TESHIMA, T ;
ANAZAWA, Y ;
MIKI, M ;
MOTOMIYA, M .
NUCLEAR MEDICINE COMMUNICATIONS, 1991, 12 (01) :47-55
[6]   TC-99(M) TECHNEGAS AND KRYPTON-81M VENTILATION SCINTIGRAPHY - A COMPARISON IN KNOWN RESPIRATORY-DISEASE [J].
JAMES, JM ;
LLOYD, JJ ;
LEAHY, BC ;
CHURCH, S ;
HARDY, CC ;
SHIELDS, RA ;
PRESCOTT, MC ;
TESTA, HJ .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (780) :1075-1082
[7]   EVALUATION OF 99TCM TECHNEGAS VENTILATION SCINTIGRAPHY IN THE DIAGNOSIS OF PULMONARY-EMBOLISM [J].
JAMES, JM ;
HERMAN, KJ ;
LLOYD, JJ ;
SHIELDS, RA ;
TESTA, HJ ;
CHURCH, S ;
STRETTON, TB .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (764) :711-719
[8]  
LEMB M, 1993, EUR J NUCL MED, V20, P576, DOI 10.1007/BF00176550
[9]  
Newman S P, 1982, Clin Phys Physiol Meas, V3, P1, DOI 10.1088/0143-0815/3/1/001
[10]   BIOLOGICAL VARIABILITY OF REGIONAL DEPOSITION OF AEROSOL-PARTICLES IN THE HUMAN RESPIRATORY-TRACT [J].
STAHLHOFEN, W ;
GEBHART, J ;
HEYDER, J .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1981, 42 (05) :348-352