CALCULATION OF CORONA ONSET VOLTAGE FOR DUCT-TYPE PRECIPITATORS

被引:39
作者
ABDELSALAM, M [1 ]
WIITANEN, D [1 ]
机构
[1] MICHIGAN TECHNOL UNIV,DEPT ELECT ENGN,HOUGHTON,MI 49931
关键词
D O I
10.1109/28.216532
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, a pure theoretical method for calculating the onset voltage of corona in duct-type precipitators that is independent of the arrangement of discharge wires relative to the collecting plates is described. This method is based on a criterion for self-recurring single electron avalanches in a known field distribution in the ionization zone surrounding the discharge wire. The results computed by this method are in reasonable agreement with those measured experimentally.
引用
收藏
页码:274 / 280
页数:7
相关论文
共 15 条
[1]   ON THE CALCULATION OF BREAKDOWN VOLTAGES FOR UNIFORM ELECTRIC-FIELDS IN COMPRESSED-AIR AND SF6 [J].
ABDELSALAM, M ;
STANEK, EK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1988, 24 (06) :1025-1030
[2]  
ABDELSALAM M, 1990, HIGH VOLTAGE ENG THE
[3]  
ALEXANDROV GN, 1956, J TECH PHYS, V26, P1679
[4]  
[Anonymous], 1978, ELECTROSTATIC PRECIP
[5]  
[Anonymous], [No title captured]
[6]  
Badaloni S., 1972, BASIC DATA AIR DISCH
[7]  
HONDA K, 1965, ELECTR ENG JPN, V85, P43
[8]  
KHALIFA M, 1990, HIGH VOLTAGE ENG
[9]  
LAWLESS PA, 1984, 5TH P S TRANSF UT PA, V2
[10]  
LOEB LB, 1965, ELECTRICAL CORONAS