FEASIBILITY OF CONTINUOUS OXYGEN DELIVERY AND CARDIAC-OUTPUT MEASUREMENT BY APPLICATION OF THE FICK PRINCIPLE

被引:14
作者
FEUSTEL, PJ
PERKINS, RJ
OPPENLANDER, JE
STRATTON, HH
COHEN, IL
机构
[1] UNION COLL,INST GRAD MANAGEMENT,SCHENECTADY,NY
[2] SUNY ALBANY,DEPT MATH & STAT,ALBANY,NY 12222
关键词
D O I
10.1164/ajrccm.149.3.8118646
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Continuous mixed venous oxygen saturation (SVO2) measurements from fiberoptic pulmonary artery catheters, arterial oxygen saturation (Sa(O2)) measurements from pulse oximetry, and minute-by-minute oxygen consumption (VO2) measurements from indirect calorimetry can be used for near-continuous estimation of cardiac output (Qt) and oxygen delivery (DO2) by application of the Fick Principle. Assumptions required for calculation of blood oxygen contents include constant hemoglobin concentration (Hgb) and constant or negligible physically dissolved oxygen. First, the influence of these assumptions on continuous Qt and DO2 determinations was tested. Unmeasured changes in Hgb resulted in substantial error in calculated Qt, whereas calculated DO2 was minimally affected. Both Qt and DO2 were little altered by errors in Pa-O2 or PVO2. Second, the effects of SVO2, Sa(O2), and VO2 measurement errors on Qt and DO2 calculations under normal and extreme conditions were quantified. Relative errors in SVO2 were increased by a factor of 4.2 in Qt estimations and by a factor of 3.2 in DO2 measurements under normal conditions. These factors increased with increasing SVO2, and thus, Qt and DO2 became increasingly unreliable as oxygen extraction fell. Third, we compared continuous measurements of Qt and DO2 with intermittent measurements made by thermodilution cardiac output and blood sampling, and found correlation coefficients of 0.85 for bt and 0.89 for DO2. Fourth, common measurement errors in VO2 and DO2 calculated in this way were found to bias regressions between VO2 and DO2, and this bias could be minimized only if the DO2 range were high and SVO2 were low. With attention paid to these problems, continuously measured dt and Lie, may be usefully applied for the assessment of DO2-dependent VO2 within a single patient.
引用
收藏
页码:751 / 758
页数:8
相关论文
共 23 条
  • [1] ARCHIE JP, 1981, ANN SURG, V193, P293
  • [2] VALUE OF CONTINUOUS MONITORING OF MIXED VENOUS-BLOOD OXYGEN-SATURATION IN THE MANAGEMENT OF CRITICALLY ILL PATIENTS
    BOUTROS, AR
    LEE, C
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (02) : 132 - 134
  • [3] THE EFFECTS OF A FLUCTUATING FIO2 ON METABOLIC MEASUREMENTS IN MECHANICALLY VENTILATED PATIENTS
    BROWNING, JA
    LINBERG, SE
    TURNEY, SZ
    CHODOFF, P
    [J]. CRITICAL CARE MEDICINE, 1982, 10 (02) : 82 - 85
  • [4] CARDIAC-OUTPUT DETERMINATION - THERMODILUTION VERSUS A NEW COMPUTERIZED FICK METHOD
    CARPENTER, JP
    NAIR, S
    STAW, I
    [J]. CRITICAL CARE MEDICINE, 1985, 13 (07) : 576 - 579
  • [5] A SYSTEMATIC METHOD FOR VALIDATION OF GAS-EXCHANGE MEASUREMENTS
    DAMASK, MC
    WEISSMAN, C
    ASKANAZI, J
    HYMAN, AI
    ROSENBAUM, SH
    KINNEY, JM
    [J]. ANESTHESIOLOGY, 1982, 57 (03) : 213 - 218
  • [6] DANEK SJ, 1980, AM REV RESPIR DIS, V122, P387
  • [7] CONTINUOUS FICK CARDIAC-OUTPUT COMPARED TO THERMODILUTION CARDIAC-OUTPUT
    DAVIES, GG
    JEBSON, PJR
    GLASGOW, BM
    HESS, DR
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (10) : 881 - 885
  • [8] INFLUENCE OF HEMATOCRIT ON CARDIOPULMONARY FUNCTION AFTER ACUTE HEMORRHAGE
    FORTUNE, JB
    FEUSTEL, PJ
    SAIFI, J
    STRATTON, HH
    NEWELL, JC
    SHAH, DM
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1987, 27 (03): : 243 - 249
  • [9] Gettinger A, 1990, Chest, V98, P786
  • [10] A CONTINUOUS CARDIAC OUTPUT RECORDER EMPLOYING THE FICK PRINCIPLE
    GUYTON, AC
    [J]. CIRCULATION RESEARCH, 1959, 7 (04) : 661 - 665