POSITIONAL PRECAUTIONS IN NEEDLE ASPIRATION LUNG-BIOPSY

被引:81
作者
MOORE, EH
SHEPARD, JAO
MCLOUD, TC
TEMPLETON, PA
KOSIUK, JP
机构
[1] Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
关键词
Biopsies; complications; 60.458; 66.732; Lung; biopsy; Pneumothorax;
D O I
10.1148/radiology.175.3.2343123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors performed 308 needle aspiration biopsies of parenchymal lung masses. The patients were then placed with the puncture site down for a period of at least 1 hour or until air leakage stopped. Coughing, talking, and activity were restricted. Complications included pneumothorax, at a rate of 25.0%, and chest tube placement, at a rate of 1.6%. In a subgroup of 262 patients who required only one pleural puncture at biopsy, a pneumothorax rate of 17.9% and a chest tube placement rate of 0.4% were encountered. When compared with a similar series of 143 control patients, significant reductions in both pneumothorax rate (P = .0004) and chest tube placement rate (P = .0001) were demonstrated.
引用
收藏
页码:733 / 735
页数:3
相关论文
共 18 条
  • [1] TRANS-THORACIC NEEDLE ASPIRATION BIOPSY - EVALUATION OF THE BLOOD PATCH TECHNIQUE
    BOURGOUIN, PM
    SHEPARD, JAO
    MCLOUD, TC
    SPIZARNY, DL
    DEDRICK, CG
    [J]. RADIOLOGY, 1988, 166 (01) : 93 - 95
  • [2] PREVENTING PNEUMOTHORAX AFTER LUNG-BIOPSY - THE ROLL-OVER TECHNIQUE
    CASSEL, DM
    BIRNBERG, FA
    [J]. RADIOLOGY, 1990, 174 (01) : 282 - 282
  • [3] PREVENTION OF PNEUMOTHORAX IN NEEDLE LUNG-BIOPSY BY BREATHING 100-PERCENT OXYGEN
    CORMIER, Y
    LAVIOLETTE, M
    TARDIF, A
    [J]. THORAX, 1980, 35 (01) : 37 - 41
  • [4] ASPIRATION BIOPSY IN THE DIAGNOSIS OF PULMONARY-DISEASE
    GIBNEY, RTN
    MAN, GCW
    KING, EG
    LERICHE, J
    [J]. CHEST, 1981, 80 (03) : 300 - 303
  • [5] GREENE RE, 1982, INTERVENTIONAL RADIO, P587
  • [6] PERCUTANEOUS NEEDLE-BIOPSY OF PULMONARY-LESIONS
    JACKSON, R
    COFFIN, LH
    DEMEULES, JE
    MILLER, DB
    DIETRICH, P
    FAIRBANK, J
    [J]. AMERICAN JOURNAL OF SURGERY, 1980, 139 (04) : 586 - 590
  • [7] USEFULNESS OF NEEDLE-BIOPSY IN CHEST LESIONS OF DIFFERENT SIZES AND LOCATIONS
    JEREB, M
    [J]. RADIOLOGY, 1980, 134 (01) : 13 - 15
  • [8] TRANS-THORACIC NEEDLE ASPIRATION BIOPSY OF BENIGN AND MALIGNANT LUNG LESIONS
    KHOURI, NF
    STITIK, FP
    EROZAN, YS
    GUPTA, PK
    KIM, WS
    SCOTT, WW
    HAMPER, UM
    MANN, RB
    EGGLESTON, JC
    BAKER, RR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (02) : 281 - 288
  • [9] MCCARTNEY T, 1974, AM J ROENTGENOL, V120, P872
  • [10] TRANS-THORACIC NEEDLE ASPIRATION - USE OF A SMALL CHEST TUBE TO TREAT PNEUMOTHORAX
    PERLMUTT, LM
    BRAUN, SD
    NEWMAN, GE
    COHAN, RH
    SAEED, M
    SUSSMAN, SK
    DUNNICK, NR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (05) : 849 - 851