PERFORMANCE OF AN ACCORDION ELECTROMAGNETIC CALORIMETER WITH LIQUID KRYPTON AND ARGON

被引:5
作者
BENARY, O
CLELAND, W
FERGUSON, I
GORDEEV, A
GORDON, H
KISTENEV, E
KROON, P
LELTCHOUK, M
LISSAUER, D
MA, H
MAKOWIECKI, D
MASLENNIKOV, A
MCCORKLE, S
ONOPRIENKO, D
ONUCHIN, A
OREN, Y
PANIN, V
PARSONS, JA
RADEKA, V
ROGERS, L
RAHM, D
RESCIA, S
RUTHERFOORD, J
SEMAN, M
SMITH, M
SONDERICKER, J
STEINER, R
STEPHANI, D
STERN, E
STUMER, I
TAKAI, H
THEMANN, H
TIKHONOV, Y
WILLIS, WJ
机构
[1] BROOKHAVEN NATL LAB,UPTON,NY 11973
[2] UNIV ARIZONA,TUCSON,AZ 85722
[3] BUDKER NUCL PHYS INST,NOVOSIBIRSK,RUSSIA
[4] COLUMBIA UNIV,NEVIS LABS,IRVINGTON,NY 10533
[5] ADELPHI UNIV,GARDEN CITY,NY 11530
[6] UNIV PITTSBURGH,PITTSBURGH,PA 15260
[7] SUNY STONY BROOK,STONY BROOK,NY 11794
[8] OAK RIDGE NATL LAB,OAK RIDGE,TN 37830
[9] TEL AVIV UNIV,IL-69978 TEL AVIV,ISRAEL
基金
美国国家科学基金会;
关键词
D O I
10.1016/0168-9002(94)90085-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Test results of a liquid krypton/argon electromagnetic calorimeter with accordion type electrode structure are presented. The test was carried out at the Brookhaven AGS in a negative beam with good electron identification at momenta 5, 10, 15, and 20 GeV/c. Results on energy resolution, linearity, pointing resolution, and muon response are presented. The results are in good agreement with Monte Carlo calculations. The energy resolution of 6.7%/square-root E was achieved using liquid krypton and 7.7%/square-root E with liquid argon, with a negligible constant term.
引用
收藏
页码:363 / 377
页数:15
相关论文
共 24 条
[1]   BEAM TESTS OF THE D-CIRCLE-DIVIDE URANIUM LIQUID ARGON END CALORIMETERS [J].
ABACHI, S ;
AHN, S ;
ABOLINS, M ;
AIHARA, H ;
AMOS, N ;
ANTIPOV, Y ;
ARONSON, SH ;
ASTUR, R ;
AVELLANEDA, R ;
AVERY, RE ;
BADEN, AR ;
BALDIN, B ;
BANTLY, J ;
BARASCH, E ;
BARTLETT, JF ;
BAZIZI, K ;
BEHNKE, T ;
BEZZUBOV, V ;
BHAT, P ;
BLAZEY, GC ;
BLESSING, S ;
BOGERT, D ;
BORCHERDING, F ;
BORDERS, J ;
BOZKO, N ;
BROCK, R ;
BROSS, AD ;
BUCHHOLZ, D ;
BULGAKOV, N ;
BURTOVOY, V ;
BUTLER, JM ;
CENCE, R ;
CHEKULAEV, S ;
CHERNY, S ;
CHEN, J ;
CHRISTENSON, JH ;
CLARK, AR ;
COCHRAN, J ;
COOPER, WE ;
CRETSINGER, C ;
CULLENVIDAL, D ;
CUTTS, D ;
DAHL, OI ;
DAVIDENKO, A ;
DE, K ;
DEMARTEAU, M ;
DENISOV, D ;
DENISOV, S ;
DHARMARATNA, W ;
DIEHL, HT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 324 (1-2) :53-76
[2]   DESIGN, CONSTRUCTION, AND PERFORMANCE OF THE ELECTROMAGNETIC MODULE OF THE D0 END CALORIMETER [J].
AIHARA, H ;
ARTHUR, AA ;
DAHL, OI ;
EBERHARD, PH ;
EDWARDS, WR ;
FULTON, RL ;
HAUGHIAN, JM ;
MADARAS, RJ ;
ROE, NA ;
SHUMAN, DB ;
SPADAFORA, AL ;
STEVENSON, ML ;
TAYLOR, JD ;
WENZEL, WA ;
CHEN, J ;
CRETSINGER, C ;
FORDEN, GE ;
MILDER, A ;
RUTHERFOORD, J ;
SHUPE, M ;
FEATHERLY, J ;
GIBBARD, BG ;
GORDON, HA ;
GUIDA, JM ;
GURYN, W ;
KAHN, S ;
PROTOPOPESCU, S ;
CUTTS, D ;
NESIC, D ;
HOFTUN, JS ;
FRANZINI, P ;
TUTS, PM ;
AMOS, N ;
BARTLETT, F ;
BHAT, P ;
CHRISTENSON, JH ;
COOPER, WE ;
DIXON, R ;
FISK, HE ;
FUESS, S ;
GRAF, N ;
HAGGERTY, H ;
ITO, AS ;
JONCKHEERE, A ;
KLIMA, B ;
LIPTON, R ;
MERRITT, W ;
PROSPER, H ;
PERYSHKIN, A ;
RAJA, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 325 (03) :393-416
[3]  
ANDRIEV B, 1993, DESY93047
[4]  
[Anonymous], 1938, COMMUNICATION
[5]   W-VALUE IN LIQUID KRYPTON [J].
APRILE, E ;
BOLOTNIKOV, A ;
CHEN, D ;
MUKHERJEE, R .
PHYSICAL REVIEW A, 1993, 48 (02) :1313-1318
[6]   PERFORMANCE OF A LIQUID ARGON ELECTROMAGNETIC CALORIMETER WITH A CYLINDRICAL ACCORDION GEOMETRY [J].
AUBERT, B ;
BAZAN, A ;
BEAUGIRAUD, B ;
COLAS, J ;
LEFLOUR, T ;
MAIRE, M ;
VIALLE, JP ;
WINGERTERSEEZ, I ;
ZOLNIEROWSKI, YP ;
GORDON, HA ;
RADEKA, V ;
RAHM, D ;
STEPHANI, D ;
BULGAKOV, N ;
CHEVALLEY, JL ;
FABJAN, CW ;
FOURNIER, D ;
GILDEMEISTER, O ;
JENNI, P ;
NESSI, M ;
NESSITEDALDI, F ;
PEPE, M ;
RICHTER, W ;
SODERQVIST, J ;
VUILLEMIN, V ;
BAZE, JM ;
GOSSET, L ;
LAVOCAT, P ;
LOTTIN, JP ;
MANSOULIE, B ;
MEYER, JP ;
RENARDY, JR ;
TEIGER, J ;
ZACCONE, H ;
BATTISTONI, G ;
CAMIN, DV ;
CAVALLI, D ;
COSTA, G ;
CRAVERO, A ;
FERRARI, A ;
GIANOTTI, F ;
MANDELLI, L ;
MAZZANTI, M ;
PERINI, L ;
SCIAMANNA, M ;
AUGE, E ;
CHASE, R ;
CHOLLET, JC ;
DELATAILLE, C ;
FAYARD, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 325 (1-2) :116-128
[7]   PERFORMANCE OF A LIQUID ARGON ELECTROMAGNETIC CALORIMETER WITH AN ACCORDION GEOMETRY [J].
AUBERT, B ;
BAZAN, A ;
CAVANNA, F ;
COLAS, J ;
LEFLOUR, T ;
VIALLE, JP ;
GORDON, HA ;
POLYCHRONAKOS, V ;
RADEKA, V ;
RAHM, D ;
STEPHANI, D ;
BAISIN, L ;
BERSET, JC ;
FABJAN, CW ;
FOURNIER, D ;
GILDEMEISTER, O ;
JENNI, P ;
LEFEBVRE, M ;
MARIN, CP ;
NESSI, M ;
NESSITEDALDI, F ;
PEPE, M ;
POLESELLO, G ;
RICHTER, W ;
SIGRIST, A ;
WILLIS, WJ ;
CAMIN, DV ;
COSTA, G ;
GIANOTTI, F ;
MANDELLI, L ;
PESSINA, G ;
ICONOMIDOUFAYARD, L ;
MERKEL, B ;
PETROFF, P ;
REPELLIN, JP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 309 (03) :438-449
[8]   PERFORMANCE OF A LIQUID ARGON ACCORDION CALORIMETER WITH FAST READOUT [J].
AUBERT, B ;
BAZAN, A ;
BEAUGIRAUD, B ;
COLAS, J ;
LEFLOUR, T ;
MAIRE, M ;
VIALLE, JP ;
WINGERTERSEEZ, I ;
ZOLNIEROWSKI, YP ;
GORDON, HA ;
RADEKA, V ;
RAHM, D ;
STEPHANI, D ;
CHEVALLEY, JL ;
FABJAN, CW ;
FOURNIER, D ;
FRANZ, A ;
GILDEMEISTER, O ;
JENNI, P ;
NESSI, M ;
NESSITEDALDI, F ;
PEPE, M ;
RICHTER, W ;
SODERQVIST, J ;
BAZE, JM ;
GOSSET, L ;
LAVOCAT, P ;
LOTTIN, JP ;
MANSOULIE, B ;
MEYER, JP ;
RENARDY, JF ;
TEIGER, J ;
ZACCONE, H ;
BATTISTONI, G ;
CAMIN, DV ;
CAVALLI, D ;
COSTA, G ;
CRAVERO, A ;
FERRARI, A ;
GIANOTTI, F ;
MANDELLI, L ;
MAZZANTI, M ;
PERINI, L ;
PESSINA, G ;
SALA, P ;
SCIAMANNA, M ;
AUGE, E ;
CHASE, R ;
CHOLLET, JC ;
DELATAILLE, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 321 (03) :467-478
[9]   LIQUID KRYPTON ELECTROMAGNETIC CALORIMETER [J].
AULCHENKO, VM ;
BUKIN, AD ;
KLIMENKO, SG ;
KOLACHEV, GM ;
LEONTIEV, LA ;
MASLENNIKOV, AL ;
ONUCHIN, AP ;
PANIN, VS ;
PELEGANCHUK, SV ;
PIVOVAROV, SG ;
RODYAKIN, VA ;
TAYURSKY, VA ;
TIKHONOV, YA ;
YURCHENKO, VI ;
LANNI, F ;
LOBIANCO, G ;
MAGGI, B ;
PALOMBO, F ;
SALA, A ;
CANTONI, P ;
FRABETTI, PL ;
STAGNI, L ;
MANFREDI, PF ;
RE, V ;
SPEZIALI, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 327 (01) :193-198
[10]   INVESTIGATION OF AN ELECTROMAGNETIC CALORIMETER BASED ON LIQUID KRYPTON [J].
AULCHENKO, VM ;
KLIMENKO, SG ;
KOLACHEV, GM ;
LEONTIEV, LA ;
ONUCHIN, AP ;
PANIN, VS ;
PRIL, YV ;
RODYAKIN, VA ;
RYLIN, AV ;
TAYURSKY, VA ;
TIKHONOV, YA ;
CANTONI, P ;
FRABETTI, PL ;
STAGNI, L ;
LOBIANCO, G ;
PALOMBO, F ;
MANFREDI, PF ;
RE, V ;
SPEZIALI, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (03) :468-474