ABSOLUTE NEUTRON-CAPTURE YIELD CALIBRATION

被引:125
作者
MACKLIN, RL
HALPERIN, J
WINTERS, RR
机构
来源
NUCLEAR INSTRUMENTS & METHODS | 1979年 / 164卷 / 01期
关键词
D O I
10.1016/0029-554X(79)90457-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The saturated resonance technique is applied more accurately (<0.5% standard deviation) and efficiently by fitting to the shape of the 4.096 eV 197Au(n,γ) peak by a least-squares procedure. © 1979.
引用
收藏
页码:213 / 214
页数:2
相关论文
共 7 条
[1]   INTERMEDIATE STRUCTURE STUDIES OF U-234 CROSS-SECTIONS [J].
JAMES, GD ;
DABBS, JWT ;
HARVEY, JA ;
HILL, NW ;
SCHINDLER, RH .
PHYSICAL REVIEW C, 1977, 15 (06) :2083-2097
[2]   HO-165 (N, GAMMA) STANDARD CROSS-SECTION FROM 3 KEV TO 450 KEV [J].
MACKLIN, RL .
NUCLEAR SCIENCE AND ENGINEERING, 1976, 59 (03) :231-236
[3]   GOLD NEUTRON-CAPTURE CROSS-SECTION FROM 3 TO 550 KEV [J].
MACKLIN, RL ;
HALPERIN, J ;
WINTERS, RR .
PHYSICAL REVIEW C, 1975, 11 (04) :1270-1279
[4]   FAST NEUTRON CAPTURE CROSS SECTION FACILITY [J].
MACKLIN, RL ;
ALLEN, BJ .
NUCLEAR INSTRUMENTS & METHODS, 1971, 91 (04) :565-&
[5]   THIN LI-6(N8ALPHA)T TRANSMISSION FLUX MONITOR [J].
MACKLIN, RL ;
HILL, NW .
NUCLEAR INSTRUMENTS & METHODS, 1971, 96 (04) :509-&
[6]  
MUGHABGHAB SF, 1973, BNL325, V1
[7]   RELIABILITY OF WEIGHTING FUNCTION FOR PULSE-HEIGHT WEIGHTING TECHNIQUE [J].
YAMAMURO, N ;
HAYASE, T ;
DOI, T ;
FUJITA, Y ;
KOBAYASHI, K ;
BLOCK, RC .
NUCLEAR INSTRUMENTS & METHODS, 1976, 133 (03) :531-536