SUPRALINEARITY AND SENSITIZATION OF THERMOLUMINESCENCE .1. A THEORETICAL TREATMENT BASED ON AN INTERACTIVE TRAP SYSTEM

被引:29
作者
SUNTA, CM
YOSHIMURA, EM
OKUNO, E
机构
[1] Laboratório de Dosimetri, Instituto de Fisica, Universidade de São Paulo, Caixa, SP, 20516
关键词
D O I
10.1088/0022-3727/27/4/027
中图分类号
O59 [应用物理学];
学科分类号
摘要
A theoretical treatment is presented for the supralinearity of thermoluminescence glow peaks. The model assumes part of the thermoluminescence trap population as interactive with the thermally disconnected deep traps. These traps produce supralinear growth ot the thermoluminescence response. The initial linear part of the response curve is assumed to be produced by the non-interactive part of the thermoluminescence trap population. The treatment enables determination of the relative concentration of deep traps. Resolution of the observed response curve into linear and supralinear parts allows determination of the relative trap populations responsible for producing the linear and supralinear parts of the response. We have also shown the procedure for determining the trap filling constant using the growth profile of the thermoluminescence glow peak of pre-dose sensitized samples. Apart from interpreting the linear and supralinear behaviour of the thermoluminescence response, the treatment provides a quantitative explanation for the pre-dose sensitization effect.
引用
收藏
页码:852 / 860
页数:9
相关论文
共 47 条
[1]   FURTHER CONSIDERATION OF TRACK-INTERACTION MODEL FOR THERMOLUMINESCENCE IN LIF(TLD-100) [J].
ATTIX, FH .
JOURNAL OF APPLIED PHYSICS, 1975, 46 (01) :81-88
[2]  
BHATT BC, 1988, RADIAT PROT DOSIM, V25, P37
[3]   THERMO-LUMINESCENCE KINETICS FOR MULTIPEAK GLOW CURVES PRODUCED BY THE RELEASE OF ELECTRONS AND HOLES [J].
BULL, RK ;
MCKEEVER, SWS ;
CHEN, R ;
MATHUR, VK ;
RHODES, JF ;
BROWN, MD .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1986, 19 (07) :1321-1334
[4]   OPTICAL-ABSORPTION AND THERMO-LUMINESCENCE IN LIF TLD-100 [J].
CALDAS, LVE ;
MAYHUGH, MR ;
STOEBE, TG .
JOURNAL OF APPLIED PHYSICS, 1983, 54 (06) :3431-3437
[5]  
CAMERON JR, 1968, THERMOLUMINESCENCE D, P162
[6]   INCOMPATIBILITY OF RADIATION-INDUCED SENSITIZATION AND RE-ESTIMATION AT LOW ABSORBED DOSES IN LIF (TLD-100) [J].
CHANDRA, B ;
LAKSHMANAN, AR ;
BHATT, RC .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1985, 10 (1-2) :77-81
[7]   DEPENDENCE OF THERMO-LUMINESCENCE SENSITIVITY ON TEMPERATURE OF IRRADIATION IN LIF (TLD-100) PHOSPHOR [J].
CHANDRA, B ;
LAKSHMANAN, AR ;
BHATT, RC .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1982, 15 (09) :1803-1816
[8]  
CHARLES MN, 1979, 1978 P INT S ADV RAD, P87
[9]   THE STRONGLY SUPERLINEAR DOSE DEPENDENCE OF THERMO-LUMINESCENCE IN SYNTHETIC QUARTZ [J].
CHEN, R ;
YANG, XH ;
MCKEEVER, SWS .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1988, 21 (09) :1452-1457
[10]  
CLAFFY EW, 1968, 2ND P INT C LUM DOS, P302