DETECTION OF INTRACRANIAL ANEURYSMS BY 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY

被引:61
作者
HORIKOSHI, T
FUKAMACHI, A
NISHI, H
FUKASAWA, I
机构
[1] NASU NEUROSURG CTR, DEPT NEUROSURG, KUROISO, TOCHIGI 325, JAPAN
[2] YAMANASHI MED COLL, DEPT NEUROSURG, YAMANASHI 40938, JAPAN
关键词
INTRACRANIAL ANEURYSM; SUBARACHNOID HEMORRHAGE; MR ANGIOGRAPHY;
D O I
10.1007/BF00588131
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this study was to investigate the reliability of magnetic resonance angiography (MRA) for detection of intracranial aneurysms. Ninety-six consecutive patients who underwent both MRA using the three-dimensional time-of-flight technique (3D TOF) with the rephase/dephase subtraction method and conventional angiography were reviewed. MRA showed 22 aneurysms in 19 patients, and conventional angiography 28 aneurysms in 23 patients. The sensitivity of MRA was thus 79% for aneurysms in 83% of patients. MRA showed no aneurysm in 67 of 73 patients without aneurysms; its specificity was therefore 92%. The 6 false positive interpretations were suspected internal carotid artery aneurysms.
引用
收藏
页码:203 / 207
页数:5
相关论文
共 20 条
[1]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[2]   DELINEATION OF UNRUPTURED CEREBRAL ANEURYSMS BY COMPUTERIZED ANGIOTOMOGRAPHY [J].
ASARI, S ;
SATOH, T ;
SAKURAI, M ;
YAMAMOTO, Y ;
SADAMOTO, K .
JOURNAL OF NEUROSURGERY, 1982, 57 (04) :527-534
[3]   ANGIOGRAPHIC FREQUENCY OF ANTERIOR CIRCULATION INTRACRANIAL ANEURYSMS [J].
ATKINSON, JLD ;
SUNDT, TM ;
HOUSER, OW ;
WHISNANT, JP .
JOURNAL OF NEUROSURGERY, 1989, 70 (04) :551-555
[4]   3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
WAGLE, W .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :139-149
[5]   PROJECTION ARTERIOGRAPHY AND VENOGRAPHY - INITIAL CLINICAL-RESULTS WITH MR [J].
EDELMAN, RR ;
WENTZ, KU ;
MATTLE, H ;
ZHAO, B ;
LIU, C ;
KIM, D ;
LAUB, G .
RADIOLOGY, 1989, 172 (02) :351-357
[6]   INTRACRANIAL ARTERIAL ANEURYSM - AN UPDATE [J].
HEROS, RC ;
KISTLER, JP .
STROKE, 1983, 14 (04) :628-631
[7]   FLOW PATTERNS IN VESSELS OF SIMPLE AND COMPLEX GEOMETRIES [J].
KARINO, T ;
GOLDSMITH, HL ;
MOTOMIYA, M ;
MABUCHI, S ;
SOHARA, Y .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 516 :422-441
[8]  
KARINO T, 1986, INT ANGIOL, V5, P297
[9]   INTRACRANIAL CIRCULATION - PRELIMINARY CLINICAL-RESULTS WITH 3-DIMENSIONAL (VOLUME) MR ANGIOGRAPHY [J].
MASARYK, TJ ;
MODIC, MT ;
ROSS, JS ;
RUGGIERI, PM ;
LAUB, GA ;
LENZ, GW ;
HAACKE, EM ;
SELMAN, WR ;
WIZNITZER, M ;
HARIK, SI .
RADIOLOGY, 1989, 171 (03) :793-799
[10]  
MASARYK TJ, 1991, MAGNETIC RESONANCE I, P1079