TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN ADULTS WITH A CONTINUOUS PRECORDIAL MURMUR

被引:6
作者
CHEN, YT
LEE, YS
KAN, MN
CHEN, JS
HU, WS
LIN, WW
WANG, KY
LIN, CJ
CHIANG, BN
机构
[1] CHUNG SHAN MED & DENT COLL, TAICHUNG 40705, TAIWAN
[2] CHINA MED COLL, TAICHUNG 40705, TAIWAN
关键词
TRANSESOPHAGEAL ECHOCARDIOGRAPHY; PATENT ARTERIAL DUCT; CORONARY ARTERY FISTULA; CORONARY SINUS OF VALSALVA; AORTOPULMONARY WINDOW;
D O I
10.1016/0167-5273(92)90109-G
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In order to assess the ability of echocardiography in the detection of intracardiac and extracardiac shunts, we studied 11 patients (aged 22-64 yr) with a continuous precordial murmur using transthoracic and transesophageal echocardiography, and correlated the results with the subsequent angiographic and surgical findings. We found that only in 5 of 6 patients with a patent arterial duct could the continuous flow pattern be detected in pulmonary artery using transthoracic echocardiography, whereas it could be readily and accurately identified by transesophageal echocardiography in all patients. The diameters of the patent arterial duct were also measured and found to be in good correlation with subsequent surgical findings (r = 0.98, p < 0.05). In 2 patients with a ruptured aneurysm of sinus of Valsalva which originated from the right coronary sinus and perforated into the right ventricle, transesophageal echocardiography gave a better image than transthoracic echocardiography. In 2 patients with coronary artery fistula, the origin and site of drainage of the coronary artery could be imaged using transesophageal echocardiography, but the course of coronary artery fistula was more easily detected by transthoracic echocardiography. In one patient with aortopulmonary window, the defect between ascending aorta and main pulmonary artery could readily be imaged by transesophageal echocardiography. We therefore recommend transesophageal echocardiography when evaluating patients with precordial continuous murmur in whom intracardiac and extracardiac shunts or defects are suspected.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 16 条
[1]  
DANIELS O, 1986, ACTA PAEDIATR SCAND, P44
[2]   DIAGNOSIS OF AORTICO-PULMONARY WINDOW BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
DONALDSON, RM ;
BALLESTER, M ;
RICKARDS, AF .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (02) :185-189
[3]   CORONARY-ARTERY FISTULA - A PULSED DOPPLER TWO-DIMENSIONAL ECHOCARDIOGRAPHIC STUDY [J].
FRIEDMAN, DM ;
RUTKOWSKI, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (13) :1652-1655
[4]   ACCURACY OF 2-DIMENSIONAL ECHOCARDIOGRAPHY IN THE DIAGNOSIS OF CONGENITAL HEART-DISEASE [J].
GUTGESELL, HP ;
HUHTA, JC ;
LATSON, LA ;
HUFFINES, D ;
MCNAMARA, DG .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (05) :514-518
[5]  
LUDOMIRSKY A, 1987, ECHOCARDIOGR-J CARD, V4, P383
[6]  
MIYATAKE K, 1984, BRIT HEART J, V51, P508
[7]  
NAKAMURA K, 1981, BRIT HEART J, V45, P219
[8]  
REEDER GS, 1980, MAYO CLIN PROC, V55, P185
[9]   REAL-TIME CROSS-SECTIONAL ECHOCARDIOGRAPHIC IMAGING AND MEASUREMENT OF PATENT DUCTUS-ARTERIOSUS IN INFANTS AND CHILDREN [J].
SAHN, DJ ;
ALLEN, HD .
CIRCULATION, 1978, 58 (02) :343-354
[10]  
SATOMI G, 1980, BRIT HEART J, V43, P351