THE TCU-380A (AG), MLCU375, AND NOVA-T IUDS AND THE IUD DAILY RELEASING 20-MU-G LEVONORGESTREL - 4 PILLARS OF IUD CONTRACEPTION FOR THE NINETIES AND BEYOND

被引:20
作者
CHI, IC
机构
[1] Family Health International, Research Triangle Park, NC 27709
关键词
D O I
10.1016/0010-7824(93)90031-2
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
With recent studies repeatedly showing results clearing the IUDs from their formerly suspected role in causing pelvic inflammatory disease (PID), very likely IUD use will further increase worldwide. While most previous IUDs have been withdrawn from the US market during the 1980s, newer and more effective IUDs have subsequently been developed; and some, marketed. Four of these devices will probably become the pillars for future IUD contraception worldwide. This review evaluates the relative performance and safety of these four devices. Consistent findings have proven the Copper-T 380A (Ag) and the Multiload-375 (MLCu375) IUDs to be safe with high and long-lasting efficacy. The Nova-T IUD showed favorable results in some studies, but showed deteriorated efficacy after three years of use in others; more studies are needed. Studies show that the IUD that daily releases 20 mug levonorgestrel (LNG-20) is associated with the highest efficacy in preventing accidental pregnancy among the four devices, but it has a uniquely high medical removal rate because of amenorrhea. This steroid-releasing device could be a high-performance IUD if this type of medical removal can be reduced through patient counseling devised according to local cultural background.
引用
收藏
页码:325 / 347
页数:23
相关论文
共 78 条
[1]  
ALLONEN H, 1989, 1186 CLIN STUD REP
[2]  
BATAR I, 1985, ADV CONTRACEPT, V1, P3298
[3]   RECOVERY OF FERTILITY AFTER USE OF THE LEVONORGESTREL 20 MCG/D OR COPPER T-380 AG INTRAUTERINE-DEVICE [J].
BELHADJ, H ;
SIVIN, I ;
DIAZ, S ;
PAVEZ, M ;
TEJADA, AS ;
BRACHE, V ;
ALVAREZ, F ;
SHOUPE, D ;
BREAUX, H ;
MISHELL, DR ;
MCCARTHY, T ;
YO, V .
CONTRACEPTION, 1986, 34 (03) :261-267
[4]   A RANDOMIZED TRIAL OF 3 COPPER IUDS - (MLCU250, MLCU375 AND NOVA-T) [J].
BRATT, H ;
SKJELDESTAD, FE ;
VALENTIN, KC .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1988, 67 (03) :247-251
[5]   A 3-YEAR EVALUATION OF TCU-380AG AND MULTILOAD CU-375 INTRAUTERINE-DEVICES [J].
CHAMPION, CB ;
BEHLILOVIC, B ;
AROSEMENA, JM ;
RANDIC, L ;
COLE, LP ;
WILKENS, LR .
CONTRACEPTION, 1988, 38 (06) :631-639
[6]  
CHI I C, 1989, Advances in Contraception, V5, P101, DOI 10.1007/BF01849478
[7]  
CHI I-C, 1986, Advances in Contraception, V2, P145, DOI 10.1007/BF01849224
[8]   THE MULTILOAD IUD - A UNITED-STATES RESEARCHERS EVALUATION OF A EUROPEAN DEVICE [J].
CHI, IC .
CONTRACEPTION, 1992, 46 (05) :407-425
[9]   PERFORMANCE OF THE COPPER T-380A INTRAUTERINE-DEVICE IN BREASTFEEDING WOMEN [J].
CHI, IC ;
POTTS, M ;
WILKENS, LR ;
CHAMPION, CB .
CONTRACEPTION, 1989, 39 (06) :603-618
[10]   IS THE COPPER T-380A DEVICE ASSOCIATED WITH AN INCREASED RISK OF REMOVAL DUE TO BLEEDING AND OR PAIN - AN ANALYSIS [J].
CHI, IC ;
FARR, G ;
THOMPSON, K ;
ACOSTA, M ;
ALVARADO, G ;
RIVERA, R ;
BANDARAGODA, J ;
BETANCOURT, JD .
CONTRACEPTION, 1990, 42 (02) :159-169