ULTRASOUND ASSESSMENT OF FETAL GROWTH

被引:36
作者
VARMA, TR [1 ]
TAYLOR, H [1 ]
BRIDGES, C [1 ]
机构
[1] ST GEORGES HOSP & MED SCH,DEPT MED PHYS,LONDON,ENGLAND
来源
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY | 1979年 / 86卷 / 08期
关键词
D O I
10.1111/j.1471-0528.1979.tb10824.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Consecutive ultrasonic measurements of the fetal head area, thorax area, abdomen area, head/thorax (H/T) area ratio and head/abdomen (H/A) area ratio were obtained from 100 patients with a normal pregnancy and from 186 patients with suspected intrauterine fetal growth retardation. Of all the measurements used, H/A area ratio was found to be most accurate in identifying intrauterine fetal growth retardation predicting 82.9 per cent at 33 weeks and 85.7 per cent at 36 to 38 weeks of gestation. This technique was also found to be useful in distinguishing between the two types of growth retardation. The H/A area ratio was helpful in identifying the growth acceleration pattern of a large baby. Copyright © 1979, Wiley Blackwell. All rights reserved
引用
收藏
页码:623 / 632
页数:10
相关论文
共 22 条
[1]   ULTRASOUND MEASUREMENT OF FETAL HEAD TO ABDOMEN CIRCUMFERENCE RATIO IN ASSESSMENT OF GROWTH RETARDATION [J].
CAMPBELL, S ;
THOMS, A .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1977, 84 (03) :165-174
[2]  
CAMPBELL S, 1968, Journal of Obstetrics and Gynaecology of the British Commonwealth, V75, P568
[3]   ULTRASONIC MEASUREMENT OF FETAL ABDOMEN CIRCUMFERENCE IN ESTIMATION OF FETAL WEIGHT [J].
CAMPBELL, S ;
WILKIN, D .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1975, 82 (09) :689-697
[4]  
Campbell S, 1974, Clin Perinatol, V1, P507
[5]   PREDICTION OF BIRTH-WEIGHT BY ULTRASOUND MEASUREMENTS OF FETUS [J].
CAMPOGRANDE, M ;
TODROS, T ;
BRIZZOLARA, M .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1977, 84 (03) :175-178
[6]   EXPERIMENTAL INTRAUTERINE GROWTH RETARDATION IN SHEEP [J].
CREASY, RK ;
RUDOLPH, AM ;
SWIET, MD ;
BARRETT, CT ;
KAHANPAA, KV .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1972, 112 (04) :566-+
[7]   ASSESSMENT OF FETAL SIZE AND GROWTH RATE BY ULTRASONIC ECHOSCOPY [J].
GARRETT, WJ ;
ROBINSON, DE .
OBSTETRICS AND GYNECOLOGY, 1971, 38 (04) :525-&
[8]  
GOLDSTEIN H, 1975, P S BIOL HUMAN FETAL, P81
[9]   ULTRASONIC MEASUREMENT DATA AS PARAMETERS FOR RECOGNITION OF INTRAUTERINE GROWTH RETARDATION [J].
HANSMANN, M ;
VOIGT, U ;
LANG, N .
ARCHIV FUR GYNAKOLOGIE, 1973, 214 (1-4) :194-197
[10]   ESTIMATION OF FETAL WEIGHT FROM ULTRASONIC MEASUREMENT OF TRUNK CIRCUMFERENCE [J].
HIGGINBOTTOM, J ;
SLATER, J ;
PORTER, G ;
WHITFIELD, CR .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1975, 82 (09) :698-701