DETERMINATION OF PEROXIDE VALUE IN VEGETABLE-OILS BY AN ORGANIC-PHASE ENZYME ELECTRODE

被引:32
作者
MANNINO, S [1 ]
COSIO, MS [1 ]
WANG, J [1 ]
机构
[1] NEW MEXICO STATE UNIV,DEPT CHEM & BIOCHEM,LAS CRUCES,NM 88003
关键词
PEROXIDE VALUE; BIOSENSORS; ORGANIC-PHASE ENZYMOLOGY;
D O I
10.1080/00032719408001074
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An organic-phase biosensor is used for measuring the peroxide value in vegetable oils. Rapid flow injection monitoring of the peroxide value is accomplished by injecting the untreated oil sample directly into a chloroform carrier solution which transports it to the downstream horseradish-peroxidase (HRP) based flow detector. The Eastman AQ polymer is used for entrapping the HRP onto the detector surface. The new scheme offers convenient monitoring of low level peroxide values and high selectivity (accrued from the biospecificity of HRP towards peroxide species and from the low operating potential). The biosensor results are consistent with those obtained by the official iodometric method. Such development should facilitate quality control testing of oil products.
引用
收藏
页码:299 / 308
页数:10
相关论文
共 11 条
[1]   AN ORGANIC-PHASE ENZYME ELECTRODE FOR CHOLESTEROL [J].
HALL, GF ;
TURNER, APF .
ANALYTICAL LETTERS, 1991, 24 (08) :1375-1388
[2]   ORGANIC-PHASE ENZYME ELECTRODES [J].
SAINI, S ;
HALL, GF ;
DOWNS, MEA ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :1-15
[3]  
SCHUBERT F, 1991, ANAL CHIM ACTA, V245, P81
[4]   MEASUREMENT OF PEROXIDE IN OILS BY CONTROLLED-POTENTIAL COULOMETRY USING A VAPOR-GROWN CARBON-FIBER ELECTRODE [J].
UCHIYAMA, S ;
SHIMAMOTO, M ;
SUZUKI, S ;
HAMAMOTO, O .
ELECTROANALYSIS, 1990, 2 (03) :259-261
[5]  
WANG J, 1992, ANAL LETT, V25, P1399, DOI 10.1080/00032719208017124
[6]   ORGANIC-PHASE ENZYMATIC ASSAYS WITH ULTRAMICROELECTRODES [J].
WANG, J ;
WU, LH ;
ANGNES, L .
ANALYTICAL CHEMISTRY, 1991, 63 (24) :2993-2994
[7]   AMPEROMETRIC BIOSENSING OF ORGANIC PEROXIDES WITH PEROXIDASE-MODIFIED ELECTRODES [J].
WANG, J ;
FREIHA, B ;
NASER, N ;
ROMERO, EG ;
WOLLENBERGER, U ;
OZSOZ, M ;
EVANS, O .
ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) :81-88
[8]   ORGANIC-PHASE BIOSENSORS BASED ON THE ENTRAPMENT OF ENZYMES WITHIN POLY(ESTER-SULFONIC ACID) COATINGS [J].
WANG, J ;
LIN, YH ;
CHEN, Q .
ELECTROANALYSIS, 1993, 5 (01) :23-28
[9]   ONLINE ORGANIC-PHASE ENZYME DETECTOR [J].
WANG, J ;
LIN, YH .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :53-58
[10]   STUDY OF OXIDATION BY CHEMI-LUMINESCENCE .4. DETECTION OF LOW-LEVELS OF LIPID HYDROPEROXIDES BY CHEMI-LUMINESCENCE [J].
YAMAMOTO, Y ;
NIKI, E ;
TANIMURA, R ;
KAMIYA, Y .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1985, 62 (08) :1248-1250