HIGH-FREQUENCY, HIGH-RESOLUTION B-SCAN ULTRASOUND IN THE ASSESSMENT OF SKIN TUMORS

被引:117
作者
HARLAND, CC
BAMBER, JC
GUSTERSON, BA
MORTIMER, PS
机构
[1] ROYAL MARSDEN HOSP, INST CANC RES, DEPT PHYS, SUTTON SM2 5PT, SURREY, ENGLAND
[2] ROYAL MARSDEN HOSP, INST CANC RES, DEPT PATHOL, SUTTON SM2 5PT, SURREY, ENGLAND
关键词
D O I
10.1111/j.1365-2133.1993.tb00229.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Sixteen skin tumours and one BCG vaccination granuloma were examined by 20-MHz B-scan ultrasound. Images were compared with closely matched histological sections of excised lesions. The correlation between histology and ultrasound was excellent for maximum tumour depth measurements (r = 0.96, P < 0.0001), but less good for maximum width (r = 0.84, P < 0.0001) because of the elastic contraction of tissue at excision. Architectural detail of lesions on histological sections corresponded well with that on ultrasound images. There was a good correlation for heterogeneity (collagen distribution vs. echo pattern (r = 0.86, P < 0.0001)), and between collagen content and echogenicity of lesions (r=0.69, P < 0.003). Strong correlations were also obtained for echogenicity vs. spacing of collagen bundles (r = -0.65, P < 0.005), echogenicity vs. collagen bundle size (r = 0.58, P < 0.02), and echogenicity vs. cellularity (r = -0.68, P < 0.003). Results for dermatofibroma were atypical, due to paradoxical low internal echogenicity and increased echo absorption. B-scanning is a reliable non-invasive method for assessing tumour dimensions, and has potential for the study of tumour characteristics for diagnostic purposes.
引用
收藏
页码:525 / 532
页数:8
相关论文
共 25 条
[1]   DETERMINING SKIN THICKNESS WITH PULSED ULTRA SOUND [J].
ALEXANDER, H ;
MILLER, DL .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1979, 72 (01) :17-19
[2]  
Bamber J.C., 1986, PHYSICAL PRINCIPLES, P118
[3]   QUANTITATIVE-EVALUATION OF REAL-TIME ULTRASOUND FEATURES OF THE BREAST [J].
BAMBER, JC ;
DEGONZALEZ, L ;
COSGROVE, DO ;
SIMMONS, P .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 :81-87
[4]  
BETTI R, 1990, Journal of Dermatology (Tokyo), V17, P247
[5]  
BREITBART EW, 1983, Z HAUTKRANKHEITEN, V58, P975
[6]   COMPUTERIZED ULTRASONIC TISSUE CHARACTERIZATION OF OCULAR TUMORS [J].
COLEMAN, DJ ;
LIZZI, FL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 96 (02) :165-175
[7]   ASSESSMENT OF AGING OF THE HUMAN-SKIN BY INVIVO ULTRASONIC-IMAGING [J].
DERIGAL, J ;
ESCOFFIER, C ;
QUERLEUX, B ;
FAIVRE, B ;
AGACHE, P ;
LEVEQUE, JL .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1989, 93 (05) :621-625
[8]   THE USE OF A-SCAN ULTRASOUND IN THE ASSESSMENT OF SMALL SKIN TUMORS [J].
EDWARDS, C ;
ALABOOSI, MM ;
MARKS, R .
BRITISH JOURNAL OF DERMATOLOGY, 1989, 121 (03) :297-304
[9]  
HOFFMANN K, 1989, Z HAUTKRANKHEITEN, V64, P851
[10]  
HOFFMANN K, 1990, HAUTARZT, V41, P333