THE EFFECT OF AGING ON SKIN BLOOD-FLOW IN THE WISTAR-KYOTO RAT

被引:4
作者
RENDELL, M
MILLIKEN, BK
MCINTYRE, SF
SATTERLEE, M
ECKERMANN, AJ
机构
[1] Creighton Diabetes Center, Omaha, NE 68131
来源
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-PHYSIOLOGY | 1995年 / 111卷 / 03期
关键词
SKIN BLOOD FLOW; AGING; LASER DOPPLER; MICROCIRCULATION; ARTERIOVENOUS ANASTOMOSES; CUTANEOUS CIRCULATION; WISTAR-KYOTO RATS; SKIN AGING;
D O I
10.1016/0300-9629(95)00007-T
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Using laser Doppler techniques in man, we have previously demonstrated that skin blood flow decreases linearly with age. In previous work, we have shown similarities in skin blood flow properties between man and the rat. Our goal was to assess a possible aging effect of skin blood flow in the rat. We determined skin blood flow sequentially in 13 Wistar-Kyoto rats, beginning at 3 months of age, then at 6, 12, 15, and 18 months. We measured flow on the back, the base of the tail, the upper leg, all nutritively (NUTR) perfused sites, and on the plantar paw surface, which is perfused chiefly by arteriovenous anastomotic (AVA) capillaries. We measured flow, microvascular volume and red blood cell velocity at basal temperature anal also heated the skin locally to 44 degrees C, to elicit maximal vasodilation. Skin blood flow declined in a linear fashion with increasing age. The decrease was in the order of 15% over 18 months and occurred at both NUTR sites and the paw. The decrease was due to reduced microvascular volume, presumably representing loss of skin capillaries. Red blood cell velocity was not reduced; in fact, it was significantly increased at several NUTR sites. The WKY rat provides an excellent model of aging of the skin micsovasculature. The changes we have demonstrated, while not identical to those we have previously demonstrated in man, are sufficiently similar to permit further exploration of the mechanisms of these changes.
引用
收藏
页码:511 / 518
页数:8
相关论文
共 31 条
[1]  
Bonner, Nossal, Model for laser Doppler measurements of blood flow in tissue, Appl. Optics, 20, pp. 2097-2107, (1981)
[2]  
Borgos, TSI's LDV Blood Flowmeter, Laser-Doppler Blood Flowmetry, pp. 73-92, (1990)
[3]  
Bronson, Rate of occurrence of lesions in 20 inbred and hybrid genotypes of rats and mice sacrificed at 6 month intervals during the first years of life, Genetic Effects on Aging II, pp. 279-358, (1990)
[4]  
Chung, Bruch, Dearlove, Endoscopic measurement of gastric mucosal flow by laser Doppler velocimetry. Effect of chronic esophageal variceal sclerosis, Am. Surg., 4, pp. 116-120, (1988)
[5]  
DiResta, Kiel, Reidel, Kaplan, Shepherd, Hybrid blood flow probe for simultaneous H<sub>2</sub> clearance and laser-Doppler velocimetry, Am J Physiol, 253, pp. G573-G581, (1987)
[6]  
Druce, Bonner, Patow, Choo, Summers, Kaliner, Response of nasal blood flow to neurohormones as measured by laser-Doppler velocimetry, J. appl. Physiol., 57, pp. 1276-1283, (1983)
[7]  
Engelhart, Meret, Kristensen, Evaluation of cutaneous blood flow responses by <sup>133</sup>Xenon washout and a laser Doppler flowmeter, J. invest. Dermat., 80, pp. 12-15, (1983)
[8]  
Evans, Rendell, Bartek, Connor, Bamisedun, Dovgan, Giitter, Thermally induced cutaneous vasodilatation in aging, J. Gerontol. Med. Sci., 48, pp. M53-M57, (1993)
[9]  
Hales, Skin arteriovenous anastomoses: control and role in thermoregulation, Cardiovascular Shunts: Phylogenetic, Ontogenetic and Clinical Aspects, pp. 433-448, (1985)
[10]  
Hazzard, Bronson, McClearn, Strong, Selection of an appropriate animal model to study aging processes with special emphasis on the use of rat strains, Journal of Gerontology, 47, pp. B63-B64, (1991)