VALIDATION AND REPRODUCIBILITY OF BIDIRECTIONAL LASER DOPPLER VELOCIMETRY FOR THE MEASUREMENT OF RETINAL BLOOD-FLOW

被引:5
作者
DAVIES, EG
SULLIVAN, PM
FITZPATRICK, M
KOHNER, EM
机构
[1] ROYAL POSTGRAD MED SCH,DEPT MED,DIABET RETINOPATHY UNIT,DIV CANE RD,LONDON W12 0NN,ENGLAND
[2] ROYAL POSTGRAD MED SCH,DIRECTORATE INFORMAT TECHNOL,LONDON W12 0HS,ENGLAND
关键词
D O I
10.3109/02713689209000736
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Bidirectional laser Doppler velocimetry (BLDV) for the measurement of retinal blood flow was validated in six anaesthetised minipigs, by comparing BLDV derived results with those obtained using radioactively labelled microspheres (RLM). The mean velocity of blood (Vmean) was calculated from the maximum red blood cell velocity measured by BLDV. Volumetric flow rate was determined from Vmean and vessel diameter, measure from monochromatic fundus photographs. Total retinal blood flow (TRBF) was calculated by summating flow values obtained for each retinal vein draining into the optic disc. A significant correlation was found between the TRBF results obtained by the two techniques (r=0.99, p<0.001). The BLDV results were between 3-35-mu-l/min lower than the corresponding RLM results (p=0.05). Values of 57 +/- 24-mu-l/min and 76 +/- 34-mu-l/min were obtained for TRBF using the BLDV and RLM techniques respectively. Reproducibility studies dies with BLDV were also performed in six anaesthetised pigs over three hours and in six normal human volunteers over two hours and two weeks. No significant difference between measurements was found with time. Ninety five percent confidence limits of +/- 9.8 % for the six pigs and +/- 8.9 % for the six human volunteers were found for measurements on the same day and at two weeks. we conclude that with a sample size of six, changes in flow of approximately 20 % can be detected using BLDV and monochromatic fundus photography.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 26 条
[2]  
ALM A, 1976, BIBLIOTHECA ANATOMIC, V16, P24
[3]   ON-LINE VOLUME FLOW-RATE AND VELOCITY PROFILE MEASUREMENT FOR BLOOD IN MICROVESSELS [J].
BAKER, M ;
WAYLAND, H .
MICROVASCULAR RESEARCH, 1974, 7 (01) :131-143
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[6]   MARGINAL PLASMA ZONE IN RETINAL MICROCIRCULATION [J].
BULPITT, CJ ;
DOLLERY, CT ;
KOHNER, EM .
CARDIOVASCULAR RESEARCH, 1970, 4 (02) :207-+
[7]  
DEUPREE DM, 1985, INVEST OPHTHALMOL S, V26, P37
[8]   LASER DOPPLER MEASUREMENTS OF BLOOD VELOCITY IN HUMAN RETINAL-VESSELS [J].
FEKE, GT ;
RIVA, CE .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (04) :526-531
[9]  
FEKE GT, 1989, INVEST OPHTH VIS SCI, V30, P58
[10]   BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES [J].
HEYMANN, MA ;
PAYNE, BD ;
HOFFMAN, JIE ;
RUDOLPH, AM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) :55-79