CHEMICAL VERSUS DUAL CURING OF RESIN INLAY CEMENTS

被引:90
作者
ELBADRAWY, WA
ELMOWAFY, OM
机构
[1] Faculty of Dentistry, University of Toronto, Toronto, Ont.
关键词
D O I
10.1016/S0022-3913(05)80109-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Dual-cure inlay resin cements polymerize both chemically and through light activation; however, clinically some aspects of the cement are not readily accessible to the light source. This study investigated the degree of cement hardening achieved through chemical curing only versus dual curing and the effect of inlay thickness on cement hardness. Disks 6 x 2.5 mm were prepared from seven commercially available cements. Eight specimens were prepared from each material; half of the specimens were cured chemically only, and the remainder were dual-cured. Knoop hardness measurements were then recorded at 1-hour, 1-day, and 1-week intervals. In addition, 24 specimens of the same dimensions were prepared from each cement. Twelve specimens were dual-cured through resin composite spacers of varying thicknesses (1 to 6 mm), and the others were cured through similar ceramic spacers, and hardness measurements were recorded. Multivariate analysis of variance revealed significant differences in hardness of chemically cured versus dual-cured specimens at the 5% level of significance for all examined cements. Significant differences were also found in the hardness of specimens dual cured through ceramic or resin composite spacers 2 to 3 mm in thickness or more versus those that were dual cured without spacer regardless of the spacer material. It is concluded that chemical curing alone was not sufficient to achieve maximum hardening of the examined cements. Cement hardness was significantly reduced when inlay thickness was 2 to 3 mm or more.
引用
收藏
页码:515 / 524
页数:10
相关论文
共 14 条
[1]  
Rekow, Computer-aided design and manufacturing in dentistry: a review of the state of the art, J Prosthet Dent, 58, pp. 512-516, (1987)
[2]  
Duret, Blouin, Duret, CAD-CAM in dentistry, J Am Dent Assoc, 117, pp. 715-720, (1988)
[3]  
Mormann, Brandestini, Lutz, Barbakow, Chairside computer-aided direct ceramic inlays, Quint Int, 20, pp. 329-339, (1989)
[4]  
Bausch, deLang, Davidson, Peters, de Gee, Clinical significance of polymerization shrinkage of composite resins, J Prosthet Dent, 48, pp. 59-67, (1982)
[5]  
Eick, Welch, Polymerization shrinkage of posterior composite resins and its possible influence on postoperative sensitivity, Quint Int, 17, pp. 103-111, (1986)
[6]  
Robinson, Moore, Swartz, Comparison of microleakage in direct and indirect composite resin restorations in vitro, Oper Dent, 12, pp. 113-116, (1987)
[7]  
Craig, Restorative dental materials, pp. 199-203, (1993)
[8]  
O'Keefe, Pease, Herrin, Variables affecting the spectral transmittance of light through porcelain veneer samples, J Prosthet Dent, 66, pp. 434-438, (1991)
[9]  
Breeding, Dixon, Caughman, The curing potential of light-activated composite resin luting agents, J Prosthet Dent, 65, pp. 512-518, (1991)
[10]  
Chan, Boyer, Curing light-activated composite cement through porcelain, J Dent Res, 68, pp. 476-480, (1989)