STUDIES ON SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY .3. REGULATION OF SYSTEM PEAK GRADIENT RETENTION FOR OBTAINING ANALYTE PEAK COMPRESSION

被引:20
作者
FORNSTEDT, T [1 ]
WESTERLUND, D [1 ]
SOKOLOWSKI, A [1 ]
机构
[1] PHARMACIA LKB BIOTECHNOL,CHEM PROD,S-75182 UPPSALA,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 506卷
关键词
D O I
10.1016/S0021-9673(01)91567-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Peak compression can be obtained when an analyte is eluted in the co-ion gradient in a large system peak. Matching of the analyte retention with this gradient was investigated. The chromatographic system was based on silanized silica and an acidic eluent, containing acetonitrile and a probe, which was an UV-detectable hydrophobic amine, protriptyline. Large system peaks, or zones, containing probe deficiencies were induced by injecting high concentrations of a hydrophobic organic anion together with cationic analytes. The back part of these system zones consisted of a steep gradient of increasing probe (co-ion) concentration, giving strongly compressed peaks when low analyte amounts were also eluted with this back-gradient. It was found that variation of the probe concentration was an efficient way of matching the retention of the system peak with analytes of widely varying retentions. © 1990.
引用
收藏
页码:61 / 74
页数:14
相关论文
共 14 条
[1]   REVERSED-PHASE ION-PAIR CHROMATOGRAPHY WITH UV-ABSORBING IONS IN THE MOBILE PHASE [J].
DENKERT, M ;
HACKZELL, L ;
SCHILL, G ;
SJOGREN, E .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :31-43
[2]   STUDIES ON SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY .2. EFFECTS ON ANALYTE PEAK COMPRESSION AND DEFORMATION [J].
FORNSTEDT, T ;
WESTERLUND, D ;
SOKOLOWSKI, A .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (13) :2645-2684
[3]   EXPERIMENTAL-STUDY OF SYSTEM PEAKS AND ELUTION PROFILES FOR LARGE CONCENTRATION BANDS IN THE CASE OF A BINARY ELUENT CONTAINING A STRONGLY SORBED ADDITIVE [J].
GOLSHANSHIRAZI, S ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1989, 461 :19-34
[4]   THEORETICAL-STUDY OF SYSTEM PEAKS AND ELUTION PROFILES FOR LARGE CONCENTRATION BANDS IN THE CASE OF A BINARY ELUENT CONTAINING A STRONGLY SORBED ADDITIVE [J].
GOLSHANSHIRAZI, S ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1989, 461 :1-18
[5]   DETECTION BY ION-PAIRING PROBES IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
HACKZELL, L ;
SCHILL, G .
CHROMATOGRAPHIA, 1982, 15 (07) :437-444
[6]   PEAK COMPRESSION EFFECTS IN ION-PAIR REVERSED-PHASE LIQUID-CHROMATOGRAPHY OF SUBSTITUTED BENZAMIDES [J].
NILSSON, LB ;
WESTERLUND, D .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1835-1840
[7]   INDIRECT DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
SCHILL, G ;
CROMMEN, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (05) :111-116
[10]   STUDIES ON SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY .1. EVALUATION OF ION-PAIR ADSORPTION CONSTANTS AND EFFECTS BY THE INJECTION OF FINITE ANALYTE AMOUNTS [J].
SOKOLOWSKI, A ;
FORNSTEDT, T ;
WESTERLUND, D .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (8-9) :1629-1662