3-DIMENSIONAL IMAGING OF CORNEAL CELLS USING IN-VIVO CONFOCAL MICROSCOPY

被引:80
作者
PETROLL, WM
CAVANAGH, HD
JESTER, JV
机构
[1] Department of Ophthalmology, Georgetown University Medical Center, Washington, District of Columbia, 20007
关键词
CONFOCAL MICROSCOPY; IN-VIVO; DIGITAL IMAGING; 3-DIMENSIONAL RECONSTRUCTION; CORNEA; EYE;
D O I
10.1111/j.1365-2818.1993.tb03344.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Confocal microscopy is a unique and powerful imaging paradigm which allows optical sectioning through intact tissue. Real-time tandem scanning confocal microscopy has previously been used to generate high-magnification two-dimensional (2-D) images of cells in living organ systems. Inherent problems with movement, however, have prevented the in vivo acquisition of complete 3-D datasets. The development of a new objective lens, used in combination with specialized real-time image acquisition procedures, has allowed sequential serial sections to be obtained in vivo from the rabbit cornea for the first time. These sections can be digitially registered and stacked on the computer to provide a 3-D reconstruction of the corneal cells. This technique should serve as a useful method for studying 3-D structures and analysing 4-D phenomena at the cellular level in living animals. Three-dimensional images of a stromal nerve in normal rabbit cornea and of fibroblasts within a rabbit corneal wound are presented as examples of current capabilities.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 29 条
  • [1] AGARD DA, 1989, METHOD CELL BIOL, V30, P353
  • [2] TANDEM SCANNING CONFOCAL MICROSCOPY (TSCM) OF NORMAL AND ISCHEMIC LIVING KIDNEYS
    ANDREWS, PM
    PETROLL, WM
    CAVANAGH, HD
    JESTER, JV
    [J]. AMERICAN JOURNAL OF ANATOMY, 1991, 191 (01): : 95 - 102
  • [3] STEREOSCOPIC IMAGES IN CONFOCAL (TANDEM SCANNING) MICROSCOPY
    BOYDE, A
    [J]. SCIENCE, 1985, 230 (4731) : 1270 - 1272
  • [4] BOYDE A, 1985, P R MICROSC SOC, V20, P130
  • [5] 3-DIMENSIONAL IMAGING IN FLUORESCENCE BY CONFOCAL SCANNING MICROSCOPY
    BRAKENHOFF, GJ
    VANDERVOORT, HTM
    VANSPRONSEN, EA
    NANNINGA, N
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 : 151 - 159
  • [6] THE INFLUENCE OF SPECIMEN REFRACTIVE-INDEX, DETECTOR SIGNAL INTEGRATION, AND NONUNIFORM SCAN SPEED ON THE IMAGING PROPERTIES IN CONFOCAL MICROSCOPY
    CARLSSON, K
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1991, 163 : 167 - 178
  • [7] CAVANAGH H D, 1990, CLAO Journal, V16, P65
  • [8] 3-DIMENSIONAL MOLECULAR-DISTRIBUTION IN SINGLE CELLS ANALYZED USING THE DIGITAL IMAGING MICROSCOPE
    FAY, FS
    CARRINGTON, W
    FOGARTY, KE
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 : 133 - 149
  • [9] GARANA RMR, 1992, INVEST OPHTH VIS SCI, V33, P3271
  • [10] Jain A. K., 1989, FUNDAMENTALS DIGITAL